Key Facts

Bolt projection
Minimum 1 inch
Strike embedment
At least three-fourths inch
Cylinder
Minimum 5-pin tumblers, cylinder guard
Connecting screws
At least one-fourth inch diameter
Adopted
Ord. 1101 § 1, 1979

Summary

Palm Springs' Building Security Regulations mandate exact deadbolt specifications on every exterior swinging door and garage-to-house door: a one-inch bolt projection, three-fourths-inch strike embedment, cutting-tool-resistant construction and a five-pin cylinder secured to 2X framing. The rules date to 1979 and are enforced by Building and Safety Services on every new residential permit.

Exterior swinging doors and swinging doors leading from the garage into living space shall be equipped with a double or single-cylinder deadbolt having a minimum projection of one inch and an embedment of at least three-fourths inch into the strike receiving the bolt. The door jamb receiving the bolt shall be securely fastened directly to 2X material. The bolt shall be constructed so as to resist cutting tool attacks. The cylinder shall have a cylinder guard, a minimum of five-pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth inch diameter.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4923139; v14 updated 2026-06-24).

Full Breakdown

170, the special residential building provisions in Article II, Building Security Regulations, requires exterior swinging doors and swinging doors from an attached garage into living space to carry a double- or single-cylinder deadbolt with at least a one-inch bolt projection and three-fourths-inch embedment into the strike, a jamb fastened directly to 2X material, a bolt built to resist cutting-tool attacks, and a cylinder with a cylinder guard, minimum five-pin tumblers, and connecting screws at least one-fourth inch in diameter. The requirement does not apply where panic hardware is required or an equivalent device is approved, and a dual locking mechanism that retracts both deadbolt and latch with one action of the interior knob may substitute if it meets the other specifications.

The same article requires the inactive leaf of double doors to carry flush bolts with at least five-eighths-inch embedment into the head and threshold, and glazing within 40 inches of a door lock to be fully tempered or burglary-resistant unless a double-cylinder deadbolt is installed. 110, pins down every hardware term used, including "bolt projection," "cylinder guard" and "dead latch," so a permit reviewer and an applicant are working from the same specification. 140 separately requires that, on occupancy, each unit in a tract or commercial development use lock combinations interchange-free from every other unit in that development, with written confirmation of compliance filed with the enforcing authority.

Violations & Fines

Section 8.04.125 makes it unlawful to erect, construct, enlarge, move, improve, equip, use, occupy or maintain a building or structure in Palm Springs contrary to Article II's security provisions. Section 8.04.120 puts the building and safety director in charge of enforcement: no construction project receives final approval or a utility release until the applicant satisfies the enforcing authority that the deadbolt, glazing and keying requirements were met.

Frequently Asked Questions

What deadbolt specs does Palm Springs require on exterior doors?
Section 8.04.170 requires a double- or single-cylinder deadbolt with at least a one-inch bolt projection and three-fourths-inch embedment into the strike, a jamb fastened to 2X material, cutting-tool-resistant bolt construction, and a cylinder with a guard, five-pin minimum tumblers and one-fourth-inch connecting screws.
Does the deadbolt rule apply to garage entry doors?
Yes. Section 8.04.170 specifically covers swinging doors leading from the garage into living space, holding them to the same deadbolt projection, embedment and cylinder-guard specifications as any other exterior swinging door.
Who checks that a new Palm Springs home meets the lock hardware code?
The building and safety director or an authorized representative enforces Article II under Section 8.04.120; no construction project gets final approval or a utility release until the applicant proves compliance with the deadbolt, flush bolt and glazing requirements.

Sources & Official References

Other rules in Palm Springs

All Palm Springs rules

California rules heatmap·Compare Palm Springs to another location·View the California building safety overview

Get notified when Door Locking Hardware in Palm Springs, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.