- Deadbolt bolt projection
- Minimum 1 inch (§ C2-8(A)(2))
- Deadbolt embedment
- At least 3/4 inch into strike
- Cylinder
- Minimum 5 pin tumblers plus cylinder guard
- Strike plate
- Minimum 16-gauge steel, bronze, or brass (§ C2-5(D))
- Keying rule
- Interchange-free locks across tract units (§ C2-4)
- Scope trigger
- New construction or 50%+ value alterations (§ C2-2)
Summary
San Ramon requires every exterior swinging door on a residential building, including the door from an attached garage into the home, to carry a single-cylinder deadbolt with a one-inch bolt throw and a five-pin cylinder under Municipal Code § C2-8(A)(2). Section C2-5 sets matching strike-plate specs, and § C2-4 bars duplicate key combinations across units in one tract.
A single or double door shall be equipped with a single-cylinder deadbolt lock. The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-fourths inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth inch in diameter. All installations shall be done so that the performance of the locking device will meet the intended antiburglary requirements.
Full Breakdown
Division C2, Chapter I, Building Security Regulations, applies to new construction and to additions or alterations that exceed fifty percent of a building's value within any twelve-month period, per § C2-2, with occupancy group R-3 exempt from that value-threshold trigger. Under § C2-8(A), every exterior swinging door of a residential building and attached garage, including the door from the garage into the dwelling, must be a solid-core wood door at least one and three-fourths inches thick, or with panels at least nine-sixteenths inch thick, and fitted with a single-cylinder deadbolt lock.
Per § C2-8(A)(2), that deadbolt must have a minimum one-inch bolt projection, be built to resist cutting-tool attack, embed at least three-fourths inch into the strike, and use a cylinder with a cylinder guard, a minimum of five pin tumblers, and connecting screws at least one-fourth inch in diameter; a dual locking mechanism retracting both deadbolt and latch by one motion of the interior knob may substitute if it meets the same specifications. gauge steel, bronze, or brass, fastened with a minimum of two screws penetrating at least two inches into solid backing, and out-swinging door hinges must use nonremovable pins or a mechanical interlock.
Section C2-4 separately requires that, once a tract or commercial development is occupied, each unit's locks use combinations that are interchange-free from every other unit built under the same general plan. Glazing within forty inches of a locking mechanism must be fully tempered or rated burglary-resistant glass under § C2-8(A)(4), and front doors without a clear vision panel need a 180-degree door viewer under § C2-8(A)(5).
Violations & Fines
Division C2, Building Security, does not carry its own fine schedule. Compliance is required as a condition of new construction and of any addition or alteration that exceeds fifty percent of a building's value within a twelve-month period under § C2-2, with occupancy group R-3 alteration work exempted from that value trigger. Doors, locks, strike plates, and keying that fall short of §§ C2-4, C2-5, and C2-8 are non-conforming and must be corrected to match the standards.
Frequently Asked Questions
What lock does San Ramon require on exterior doors?
Does San Ramon regulate the door itself, not just the lock?
Can every unit in a new development use the same key?
Which buildings does San Ramon's door security code apply to?
Sources & Official References
Other rules in San Ramon
California rules heatmap·Compare San Ramon to another location·View the California building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.