Yucaipa, CA Building Safety: Door Locking Hardware (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Required peephole
Wide-angle, lets resident see out without being seen
Required lock
Deadbolt attached to the construction studding
Not sufficient
Attachment to the doorjamb or trim
Where it applies
RM districts under the Multiple Residential Design Standards, except RM-24
Peephole alternative approved by
Planning Commission and/or City Council
First offense fine
$50 to $100

Summary

In the City of Yucaipa, California, every door giving ingress and egress to a dwelling unit under the Multiple Residential Design Standards needs a wide-angle peephole and a deadbolt lock attached to the construction studding. Yucaipa Development Code § 88.0210(g) says attachment to the doorjamb or trim is not enough.

(g) Each door providing ingress and egress to any dwelling unit subject to this ordinance shall be equipped with the following devices: (1) A peephole allowing a person inside the unit to see, at a wide angle, persons outside of the unit at the door, without the person inside being seen. The Planning Commission and/or City Council may consider other options to a peephole which provide like security features. (2) A deadbolt lock attached to the construction studding. Attachment to the doorjamb or trim shall not be sufficient to comply with the terms of this ordinance.

Full Breakdown

Yucaipa Development Code § 88.0210(g) sets the door hardware rule for the City of Yucaipa's multiple-unit residential projects. Each door providing ingress and egress to any dwelling unit subject to the ordinance must carry two devices. First, a peephole allowing a person inside the unit to see, at a wide angle, persons outside of the unit at the door, without the person inside being seen. The Planning Commission and/or City Council can consider other options to a peephole that provide like security features. Second, a deadbolt lock attached to the construction studding. Attachment to the doorjamb or trim is not sufficient to comply.

The rule reaches only projects under Chapter 2, Multiple Residential Design Standards. Section 88.0201(b) applies those standards in all Residential land use districts where the residential designation is preceded by the RM designation, except for RM-24. Under § 88.0201(c), a Conditional Use Permit and a public hearing are required for proposed multi-family projects of more than 10 units in areas zoned RM, and a small lot subdivision instead files a subdivision map. The section read here does not extend the peephole and deadbolt requirement to single-family doors. The section was last amended by Ord. 465 § 8 in 2025.

Security hardware is one piece of the dwelling amenities package in § 88.0210. Subsection (f) requires at least three items from a list of 14, and that list includes a security alarm system and an automatic garage door opener. Subsection (a) sets minimum unit sizes of 750 square feet for one bedroom, 900 square feet for two bedrooms and 1,050 square feet for three or more bedrooms, and subsection (b) bars any building structure from exceeding two stories. Plans are reviewed by the City Architect and approved by the Planning Commission and/or City Council under § 88.0220.

Violations & Fines

A violation of the Development Code is an infraction or misdemeanor under § 81.0205. A first offense carries a fine of not less than $50 and not more than $100, a second offense not less than $100 and not more than $200, and a third offense is a misdemeanor with fines from $500 to $1,000, six months in jail, or both. Each day is a new and separate offense, and § 81.0210 names the Building Official and Code Enforcement Officer among the enforcers.

Frequently Asked Questions

Does a single-family home in Yucaipa need a peephole and deadbolt under this rule?
Not under § 88.0210(g). It covers each door providing ingress and egress to a dwelling unit subject to the Multiple Residential Design Standards, which § 88.0201(b) applies in residential districts designated RM, except RM-24. The section read here does not extend the requirement to single-family doors in the City of Yucaipa.
Is a deadbolt screwed into the doorjamb acceptable?
No. Section 88.0210(g)(2) requires a deadbolt lock attached to the construction studding and states that attachment to the doorjamb or trim shall not be sufficient to comply. The attachment point is part of the standard, not just the presence of the lock.
Can a developer use something other than a peephole?
Yes, with approval. Section 88.0210(g)(1) says the Planning Commission and/or City Council can consider other options to a peephole which provide like security features. The default device is a peephole giving a wide-angle view of persons outside the door without the person inside being seen.
What review do large multi-family projects face in Yucaipa?
Under § 88.0201(c), proposed multi-family projects of more than 10 units in areas zoned RM need a Conditional Use Permit and a public hearing. A small lot subdivision files a subdivision map instead, and all common space areas are identified as lettered lots.

Sources & Official References

Other rules in Yucaipa

All Yucaipa rules

California rules heatmap·Compare Yucaipa to another location·View the California building safety overview

Get notified when Door Locking Hardware in Yucaipa, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Door Locking Hardware in Nearby Cities

How other cities in San Bernardino County handle door locking hardware.

Chino, CA
Some Restrictions
Ontario, CA
Some Restrictions
Rialto, CA
Some Restrictions