Yucaipa, CA Building Safety: Plumbing Permits (2026)
Key Facts
- Adopted code
- California Plumbing Code, 2025 Edition (Part 5, Title 24)
- Base standard
- Uniform Plumbing Code, 2024 Edition (IAPMO)
- Backwater valve trigger
- Flood level rims less than 12 inches above upstream manhole cover
- Garage floors
- Backwater valves and cleanouts prohibited
- Fees
- Set by City Council resolution
- Appeals
- City Council acts as the board of appeals
Summary
In the City of Yucaipa, California, plumbing work is governed by the California Plumbing Code, 2025 Edition, which amends the 2024 Uniform Plumbing Code and is adopted by Yucaipa Municipal Code § 15.04.035 together with permit issuance and fee collection. Local amendments require backwater valves on low fixtures and prohibit both backwater valves and cleanouts on garage floors.
Except as hereinafter provided, the California Plumbing Code, 2025 Edition (Part 5, Title 24, California Code of Regulations), including all appendices, which incorporates and amends the Uniform Plumbing Code, 2024 Edition, published by the International Association of Plumbing and Mechanical Officials, including Uniform Plumbing Code Appendices thereto, not in conflict with the California Plumbing Code, is hereby adopted by reference as the Plumbing Code of the City of Yucaipa for regulating the design, construction, quality of materials, erections, installation, alteration, repair, location, replacement, addition to, use or maintenance of plumbing systems in the City of Yucaipa, and providing for the issuance of permits and collection of fees therefor; ... 710.1 Backflow Protection. Drainage piping serving fixtures which have flood level rims located less than 12" above the elevation of the next upstream manhole cover of the public sewer serving such drainage piping shall be protected from back flow of sewage by installing an approved type of backwater valve.
Full Breakdown
Section 15.04.035 adopts the California Plumbing Code, 2025 Edition (Part 5, Title 24, California Code of Regulations), including all appendices, as the Plumbing Code of the City of Yucaipa. It incorporates and amends the Uniform Plumbing Code, 2024 Edition, published by the International Association of Plumbing and Mechanical Officials, and adopts the IAPMO Installations Standards, 2024 Edition. The code covers design, installation, alteration, repair, replacement and maintenance of plumbing systems in the City of Yucaipa, with permits and fee collection, and a copy is kept at the Building Division of the Development Services Department for public inspection.
Two local amendments apply. Section 710.1 requires an approved backwater valve on drainage piping that serves fixtures with flood level rims located less than 12 inches above the elevation of the next upstream manhole cover of the public sewer. Fixtures served by a private sewage disposal can have their flood level rims at the elevation of that manhole cover, but fixtures above that elevation cannot discharge through the backwater valve. Backwater valves are prohibited on garage floors. Section 719.1 puts cleanouts inside the building near the connection between the building drain and the building sewer, or outside the building at the lower end of the building drain and extended to grade, and prohibits cleanouts on garage floors.
Permit administration comes from § 15.04.015. Section 109.2 sends plumbing permit fees to the most recent City Council resolution, and the plan review fee is due when plans are submitted. A residential permit becomes invalid unless work starts within 365 days of issuance, or if work is suspended or abandoned for 180 days between required inspections, and the Building Official can grant one written 180-day extension. A re-inspection fee under Section 109.8 can be imposed when the work called for inspection is not complete, though not the first time a job is rejected. The City Council serves as the board of appeals.
Violations & Fines
Plumbing work begun without a permit draws a special investigation and an investigation fee equal to the permit fee under Section 109.7 of § 15.04.015. Violations of the Yucaipa Municipal Code are misdemeanors punishable by a fine of up to $1,000, up to six months in jail, or both, or infractions at up to $100, $200 and $500 for the first, second and third violation within one year (§ 1.12.040). A backwater valve or cleanout installed on a garage floor breaks the local amendments and fails inspection.
Frequently Asked Questions
Which plumbing code applies in the City of Yucaipa?
When does Yucaipa require a backwater valve?
Where can a cleanout go in Yucaipa?
How are Yucaipa plumbing permit fees set?
Sources & Official References
Other rules in Yucaipa
California rules heatmap·Compare Yucaipa to another location·View the California building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Plumbing Permits in Nearby Cities
How other cities in San Bernardino County handle plumbing permits.