Skip to main content
CityRuleLookup

Yucaipa, CA Building Safety: Plumbing Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Adopted code
California Plumbing Code, 2025 Edition (Part 5, Title 24)
Base standard
Uniform Plumbing Code, 2024 Edition (IAPMO)
Backwater valve trigger
Flood level rims less than 12 inches above upstream manhole cover
Garage floors
Backwater valves and cleanouts prohibited
Fees
Set by City Council resolution
Appeals
City Council acts as the board of appeals

Summary

In the City of Yucaipa, California, plumbing work is governed by the California Plumbing Code, 2025 Edition, which amends the 2024 Uniform Plumbing Code and is adopted by Yucaipa Municipal Code § 15.04.035 together with permit issuance and fee collection. Local amendments require backwater valves on low fixtures and prohibit both backwater valves and cleanouts on garage floors.

Except as hereinafter provided, the California Plumbing Code, 2025 Edition (Part 5, Title 24, California Code of Regulations), including all appendices, which incorporates and amends the Uniform Plumbing Code, 2024 Edition, published by the International Association of Plumbing and Mechanical Officials, including Uniform Plumbing Code Appendices thereto, not in conflict with the California Plumbing Code, is hereby adopted by reference as the Plumbing Code of the City of Yucaipa for regulating the design, construction, quality of materials, erections, installation, alteration, repair, location, replacement, addition to, use or maintenance of plumbing systems in the City of Yucaipa, and providing for the issuance of permits and collection of fees therefor; ... 710.1 Backflow Protection. Drainage piping serving fixtures which have flood level rims located less than 12" above the elevation of the next upstream manhole cover of the public sewer serving such drainage piping shall be protected from back flow of sewage by installing an approved type of backwater valve.

Full Breakdown

Section 15.04.035 adopts the California Plumbing Code, 2025 Edition (Part 5, Title 24, California Code of Regulations), including all appendices, as the Plumbing Code of the City of Yucaipa. It incorporates and amends the Uniform Plumbing Code, 2024 Edition, published by the International Association of Plumbing and Mechanical Officials, and adopts the IAPMO Installations Standards, 2024 Edition. The code covers design, installation, alteration, repair, replacement and maintenance of plumbing systems in the City of Yucaipa, with permits and fee collection, and a copy is kept at the Building Division of the Development Services Department for public inspection.

Two local amendments apply. Section 710.1 requires an approved backwater valve on drainage piping that serves fixtures with flood level rims located less than 12 inches above the elevation of the next upstream manhole cover of the public sewer. Fixtures served by a private sewage disposal can have their flood level rims at the elevation of that manhole cover, but fixtures above that elevation cannot discharge through the backwater valve. Backwater valves are prohibited on garage floors. Section 719.1 puts cleanouts inside the building near the connection between the building drain and the building sewer, or outside the building at the lower end of the building drain and extended to grade, and prohibits cleanouts on garage floors.

Permit administration comes from § 15.04.015. Section 109.2 sends plumbing permit fees to the most recent City Council resolution, and the plan review fee is due when plans are submitted. A residential permit becomes invalid unless work starts within 365 days of issuance, or if work is suspended or abandoned for 180 days between required inspections, and the Building Official can grant one written 180-day extension. A re-inspection fee under Section 109.8 can be imposed when the work called for inspection is not complete, though not the first time a job is rejected. The City Council serves as the board of appeals.

Violations & Fines

Plumbing work begun without a permit draws a special investigation and an investigation fee equal to the permit fee under Section 109.7 of § 15.04.015. Violations of the Yucaipa Municipal Code are misdemeanors punishable by a fine of up to $1,000, up to six months in jail, or both, or infractions at up to $100, $200 and $500 for the first, second and third violation within one year (§ 1.12.040). A backwater valve or cleanout installed on a garage floor breaks the local amendments and fails inspection.

Frequently Asked Questions

Which plumbing code applies in the City of Yucaipa?
The California Plumbing Code, 2025 Edition (Part 5, Title 24, California Code of Regulations), which incorporates and amends the Uniform Plumbing Code, 2024 Edition, from IAPMO. Section 15.04.035 adopts it for plumbing systems in the City of Yucaipa, along with the IAPMO Installations Standards, 2024 Edition, and ties it to permits and fees.
When does Yucaipa require a backwater valve?
When drainage piping serves fixtures with flood level rims located less than 12 inches above the elevation of the next upstream manhole cover of the public sewer. Those fixtures must be protected from back flow of sewage by an approved type of backwater valve, and backwater valves are prohibited on garage floors.
Where can a cleanout go in Yucaipa?
Section 719.1 places cleanouts inside the building near the connection between the building drain and the building sewer, or outside the building at the lower end of the building drain and extended to grade. Cleanouts are prohibited on garage floors.
How are Yucaipa plumbing permit fees set?
By City Council resolution. Section 109.2 of the city's building code amendments refers to the most recent resolution on fees for building, plumbing, mechanical, electrical, solar, fire and grading permits, and the plan review fee must be paid when plans and specifications are submitted. A refund of not more than 80 percent applies when no work has been done.

Sources & Official References

Other rules in Yucaipa

All Yucaipa rules

California rules heatmap·Compare Yucaipa to another location·View the California building safety overview

Get notified when Plumbing Permits in Yucaipa, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Plumbing Permits in Nearby Cities

How other cities in San Bernardino County handle plumbing permits.

Chino, CA
Some Restrictions
Fontana, CA
Some Restrictions
Hesperia, CA
Some Restrictions
Ontario, CA
Some Restrictions
Rancho Cucamonga, CA
Some Restrictions
Rialto, CA
Some Restrictions
San Bernardino, CA
Some Restrictions
Victorville, CA
Some Restrictions