Bensalem, PA Building Safety: Electrical Permits (2026)
Key Facts
- Adopted code
- National Electrical Code, 1999 Edition
- Inspecting authority
- Dept. of Building and Planning
- Certificate required before
- electric current supplied
- Max fine per violation
- $1,000
- Aluminum wire
- banned except limited exceptions
Summary
Bensalem Township has adopted the 1999 National Electrical Code as its Electrical Code, and no building can have electric current supplied until the Township's Department of Building and Planning issues a certificate of inspection. Violations run up to $1,000 per day.
Bensalem Township hereby adopts and incorporates herein as part of its Electrical Code the National Electrical Code, 1999 Edition, published by the National Fire Protection Association and repeals Ordinance Number 97-34 and the whole thereof, save and except for that part which is amended in section 89-7 thereof. ... No electrical wiring system may be used or electric current supplied to a lot, piece of ground, building or structure in Bensalem Township until a certificate of inspection has been issued by the Township of Bensalem. ... Any and all violations of this chapter or any part of this chapter shall be deemed a summary offense and each and every violation shall be fined a sum not in excess of $1,000.00 for each violation. Each day that a violation continues shall constitute a separate offense.
Full Breakdown
Bensalem Township Code Chapter 89, Electrical Standards, adopts the National Electrical Code, 1999 Edition, published by the National Fire Protection Association, as Section 89-1 states, repealing the prior 1997 electrical ordinance except for the local amendment in Section 89-7. Local amendments in Sections 89-2 through 89-6 modify the national code: aluminum wire is banned in any Bensalem building except for limited service-conductor uses with oxide-inhibiting joint compound at terminations, raceways must protect fixed appliances and surface-mounted equipment in unfinished basements and garages of new residential dwellings, existing aluminum connections must be re-terminated with an approved system before occupancy, nonresidential fixed wiring must use metal raceways or listed cable types, and ground-fault protection is required for 125-volt 15 and 20 amp receptacles within six feet of a sink.
Section 89-8 provides that stricter Commonwealth statutes or regulations supersede the chapter. Section 89-9 bars supplying electric current to any lot or structure until the Township of Bensalem issues a certificate of inspection, and Section 89-10 designates the Township Department of Building and Planning, or its approved representative, as the sole inspector of electrical wiring, equipment and installation methods townshipwide. Section 89-12 further declares any structure or service equipment maintained contrary to the chapter a public nuisance, abatable under the Second Class Township Code.
Violations & Fines
Section 89-11 makes any violation of Chapter 89 a summary offense, with a fine not exceeding $1,000 for each violation, and each day a violation continues constitutes a separate offense. Noncompliant structures or equipment may also be declared a public nuisance under Section 89-12 and abated accordingly.
Frequently Asked Questions
Which electrical code does Bensalem Township enforce?
Can I turn on power to a new building without an inspection?
Is aluminum wiring allowed in Bensalem buildings?
Sources & Official References
Other rules in Bensalem
Compare Bensalem to another location·View the Pennsylvania building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.