Pawtucket, RI Building Safety: Electrical Permits (2026)
Key Facts
- Governing code
- RI State Building Code, § 186-1
- One-family minimum service
- 100 amperes
- Three/four-family minimum service
- 150 amperes
- Five/six-family minimum service
- 200 amperes
- First Fire District wiring
- Metal-clad cable or rigid conduit only
Summary
Every electrical installation in Pawtucket must strictly conform to the Rhode Island State Building Code and city ordinances under City Code § 186-1. Homes need a minimum 100-amp service entrance, three- and four-family buildings need 150 amps, and five- and six-family buildings need 200 amps under § 186-3.
No electrical construction or installation work shall be performed that does not strictly conform to the electrical standards currently in effect under the Rhode Island State Building Code, the laws of the state and the ordinances, rules and regulations of the City of Pawtucket. ... Service-entrance conductors shall have sufficient ampacity to carry the calculated design load in accordance with § 186-1 and in accordance with the following standards: A. One-family dwelling: one hundred (100) amperes, minimum. B. Three- or four-family dwelling: one hundred fifty (150) amperes, minimum. C. Five- or six-family dwelling: two hundred (200) amperes, minimum.
Full Breakdown
Chapter 186, Electrical Standards, dates to 1967 and has been amended several times, most recently to set specific service capacity minimums. Section 186-1 is the general conformance clause: no electrical construction or installation work may be performed unless it strictly conforms to the electrical standards currently in effect under the Rhode Island State Building Code, state law, and the city's own ordinances, rules and regulations. That incorporates the state-adopted National Electrical Code by reference rather than printing amperage tables for every fixture locally. Section 186-2, added in 1971, imposes an extra layer inside the First Fire District: all wiring there must be metal-clad cable, rigid metal conduit, metallic tubing or structural metal raceways, a stricter standard than typical residential wiring methods allowed elsewhere in the city, reflecting the density and fire history of Pawtucket's old mill-era core.
Section 186-3, added in 1972, sets minimum service-entrance ampacity by building type: a one-family dwelling needs at least 100 amperes, a three- or four-family dwelling needs at least 150 amperes, and a five- or six-family dwelling needs at least 200 amperes, all calculated to carry the design load required under § 186-1. Permits and fees for this work sit in a related chapter, Chapter 202, Article I (Electrical Fees), and enforcement runs through the city's Building/Electrical Inspector under the state building code framework rather than a separate Pawtucket-only inspection scheme.
Violations & Fines
Chapter 186 does not print its own fine schedule; violations of the electrical conformance requirement are enforced as building code violations through the city's Building Official under the Rhode Island State Building Code framework referenced directly in § 186-1. Work that does not conform can be red-tagged and barred from final inspection sign-off until it is brought up to the applicable NEC and state building code standard.
Frequently Asked Questions
What electrical code applies to work in Pawtucket?
What size electrical service does a Pawtucket house need?
Are there extra wiring rules in older parts of Pawtucket?
Sources & Official References
Other rules in Pawtucket
Compare Pawtucket to another location·View the Rhode Island building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Electrical Permits in Nearby Cities
How other cities in this county handle electrical permits.