Skip to main content
CityRuleLookup

Lafayette, LA Building Safety: Elevator Maintenance (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
LCG PMC § 26-279, Elevators/escalators
Maintenance standard
ASME A17.1 compliance required
Inspection schedule
ASME A17.1 Appendix N intervals
Certificate posting
Displayed in car or operator's office
Multi-elevator rule
At least 1 running while occupied

Summary

Lafayette requires every elevator, escalator, and dumbwaiter to be maintained to ASME A17.1 and inspected on that standard's Appendix N schedule under Sec. 26-279, with the current inspection certificate posted where the public or the building official can see it, and at least one elevator kept running whenever a multi-elevator building is occupied.

(a)General. Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certificate of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, be available for public inspection in the office of the building operator or be posted in a publicly conspicuous location approved by the building official. The inspection and tests shall be performed at not less than the periodic intervals listed in ASME A17.1, Appendix N, except where otherwise specified by the authority having jurisdiction.(b)Elevators. In Buildings equipped with passenger elevators, not less than one elevator shall be maintained in operation at all times when the building is occupied. Exception: Buildings equipped with only one elevator shall be permitted to have the elevator temporarily out of service for testing or servicing.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 65).

Full Breakdown

Sec. 1, Appendix N, unless the authority having jurisdiction specifies something else. Compliance isn't just a maintenance file: the section requires the current certificate of inspection to be physically on display inside the elevator car itself, or attached to the escalator or dumbwaiter, or at minimum available for public inspection in the building operator's office or posted somewhere the building official has approved as conspicuous. For buildings with multiple passenger elevators, Sec. 26-279(b) requires at least one car to stay in service at all times the building is occupied, a single-elevator building gets a narrow exception allowing that one elevator to go down temporarily for testing or servicing, but a multi-elevator building can't take every car offline at once.

Enforcement runs through the building official's inspection authority in Sec. 26-257, and a failed or overdue inspection certificate is itself evidence of noncompliance during a PMC inspection.

Violations & Fines

A building operator without a current, posted ASME A17.1 inspection certificate, or one running an elevator past its Appendix N testing interval, is in violation of Sec. 26-279; the building official can order the equipment taken out of service or corrected, escalating to the administrative hearing process under chapter 26, article XVI if the operator doesn't comply.

Frequently Asked Questions

How often must Lafayette elevators be inspected?
Sec. 26-279(a) ties inspection frequency to ASME A17.1, Appendix N, which sets the periodic testing intervals, unless the authority having jurisdiction specifies a different schedule for a particular piece of equipment; the exact interval is set by the equipment category and use classification in that national standard, not a single number in the local code.
Where does the elevator inspection certificate have to be posted?
It must be on display inside the elevator, attached to the escalator or dumbwaiter, available for public inspection in the building operator's office, or posted in a location the building official has approved as publicly conspicuous.
Can a Lafayette building take all its elevators offline for servicing?
Only if it has just one elevator. Sec. 26-279(b) requires buildings with more than one passenger elevator to keep at least one running at all times the building is occupied, and the single-elevator exception exists so that car can be tested or serviced without a building-wide shutdown.

Sources & Official References

Other rules in Lafayette

All Lafayette rules

Compare Lafayette to another location·View the Louisiana building safety overview

Get notified when Elevator Maintenance in Lafayette, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.