Salem, OR Building Safety: Fire Sprinkler Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
SRC 59.230
Separation required
1-hour fire-resistive, between classifications
Boiler/heating rooms
same 1-hour separation required
Alternative
approved fire sprinkler system may substitute
Applies to
multi-classification residential structures
Civil penalty ceiling
$2,000 per violation

Summary

Salem doesn't mandate sprinklers in every dwelling; instead SRC 59.230 requires a one-hour fire-resistive separation between different dwelling classifications sharing a residential structure and around boiler or central heating rooms, and lets owners install an approved sprinkler system instead.

(a)When a residential structure contains more than one dwelling classification, each part of the residential structure comprising a separate or distinct occupancy shall be separated from each other occupancy in the residential structure by not less than a one-hour fire-resistive occupancy separation meeting the requirements for such occupancy separations as specified in the Building Code.(b)In all residential structures, each room containing a boiler or central heating plant shall be separated from the rest of the residential structure by not less than a one hour fire resistive occupancy separation.(c)An approved fire sprinkler system may be used in lieu of fire-resistive separation as otherwise required by this section.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 26 Update 1).

Full Breakdown

230(a) applies when a residential structure contains more than one dwelling classification under one roof, for example an apartment house sharing a building with a rooming house or hotel unit: each classification must be separated from the others by not less than a one-hour fire-resistive occupancy separation meeting the Building Code's requirements for such separations. Subsection (b) applies the same one-hour standard to any room containing a boiler or central heating plant in any residential structure, separating it from the rest of the building. Subsection (c) is the sprinkler provision itself: an approved fire sprinkler system may be used in lieu of the fire-resistive separation otherwise required by the section, meaning sprinklers are an alternative compliance path rather than a blanket requirement layered on top of separation walls. 230(c) is specific to multi-classification structures and boiler rooms. 600.

Violations & Fines

Operating a multi-classification residential structure or boiler room without either the required one-hour fire-resistive separation or an approved substitute sprinkler system under SRC 59.230 is an infraction under SRC 59.990(a)(1), with each day of noncompliance a separate violation. The City may additionally impose a civil penalty of up to $2,000 per violation under SRC 59.990(b).

Frequently Asked Questions

Does Salem require fire sprinklers in rental housing?
Not as a blanket rule. SRC 59.230(c) lets owners install an approved fire sprinkler system as a substitute for the one-hour fire-resistive separation otherwise required between different dwelling classifications sharing a structure, or around a boiler or central heating room.
What counts as a 'dwelling classification' needing fire separation in Salem?
The rule applies where one residential structure mixes classifications, for example an apartment house sharing a building with a rooming house or hotel unit. Each classification must be separated by at least a one-hour fire-resistive occupancy separation under SRC 59.230(a), unless replaced by sprinklers.
Is a boiler room required to be fire-separated in a Salem apartment building?
Yes. SRC 59.230(b) requires every room containing a boiler or central heating plant in a residential structure to be separated from the rest of the building by at least a one-hour fire-resistive occupancy separation, or protected instead by an approved fire sprinkler system under subsection (c).

Sources & Official References

Other rules in Salem

All Salem rules

Compare Salem to another location·View the Oregon building safety overview

Get notified when Fire Sprinkler Requirements in Salem, OR changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.