Salem, OR Building Safety: Fire Sprinkler Requirements (2026)
Key Facts
- Governing section
- SRC 59.230
- Separation required
- 1-hour fire-resistive, between classifications
- Boiler/heating rooms
- same 1-hour separation required
- Alternative
- approved fire sprinkler system may substitute
- Applies to
- multi-classification residential structures
- Civil penalty ceiling
- $2,000 per violation
Summary
Salem doesn't mandate sprinklers in every dwelling; instead SRC 59.230 requires a one-hour fire-resistive separation between different dwelling classifications sharing a residential structure and around boiler or central heating rooms, and lets owners install an approved sprinkler system instead.
(a)When a residential structure contains more than one dwelling classification, each part of the residential structure comprising a separate or distinct occupancy shall be separated from each other occupancy in the residential structure by not less than a one-hour fire-resistive occupancy separation meeting the requirements for such occupancy separations as specified in the Building Code.(b)In all residential structures, each room containing a boiler or central heating plant shall be separated from the rest of the residential structure by not less than a one hour fire resistive occupancy separation.(c)An approved fire sprinkler system may be used in lieu of fire-resistive separation as otherwise required by this section.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 26 Update 1).
Full Breakdown
230(a) applies when a residential structure contains more than one dwelling classification under one roof, for example an apartment house sharing a building with a rooming house or hotel unit: each classification must be separated from the others by not less than a one-hour fire-resistive occupancy separation meeting the Building Code's requirements for such separations. Subsection (b) applies the same one-hour standard to any room containing a boiler or central heating plant in any residential structure, separating it from the rest of the building. Subsection (c) is the sprinkler provision itself: an approved fire sprinkler system may be used in lieu of the fire-resistive separation otherwise required by the section, meaning sprinklers are an alternative compliance path rather than a blanket requirement layered on top of separation walls. 230(c) is specific to multi-classification structures and boiler rooms. 600.
Violations & Fines
Operating a multi-classification residential structure or boiler room without either the required one-hour fire-resistive separation or an approved substitute sprinkler system under SRC 59.230 is an infraction under SRC 59.990(a)(1), with each day of noncompliance a separate violation. The City may additionally impose a civil penalty of up to $2,000 per violation under SRC 59.990(b).
Frequently Asked Questions
Does Salem require fire sprinklers in rental housing?
What counts as a 'dwelling classification' needing fire separation in Salem?
Is a boiler room required to be fire-separated in a Salem apartment building?
Sources & Official References
Other rules in Salem
Compare Salem to another location·View the Oregon building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.