Key Facts

Footing inspection
before concrete is poured
Frame inspection
after rough-in, before drywall
Final inspection
required before occupancy
Written release
needed to proceed past each stage

Summary

Roswell requires staged inspections, footing, framing, and final, before any permitted building work can proceed to the next step or receive occupancy.

The chief building inspector upon notification from the permit holder or his agent shall make the following inspections and such other inspections as necessary, and shall either release that portion of the construction or shall notify the permit holder or his agent of any violations which must be corrected in order to comply with the technical code:

(a)Building:(1)Footing/Foundation/Foundation Wall Inspection: To be made after trenches are excavated, the reinforcement in place, and the forms erected, prior to the placing of concrete.(2)Slab/Monolithic Slab Inspection: To be made prior to the placing of concrete.(3)Frame Inspection: To be made after the roof, all framing, fire blocking and bracing, are in place, all concealed wiring, all pipes, chimneys, ducts and vents are complete.(4)Moisture Barrier Inspection: To be made prior to the installation of the exterior finish material.(5)Final Inspection: To be made after the building is completed and ready for occupancy.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 17 | Unified Development Code: Supplement 5).

Full Breakdown

Under the general Code of Ordinances, Roswell's chief building inspector must inspect construction at defined stages: footing/foundation before concrete is poured, framing after rough-in work, and a final inspection before occupancy, plus parallel electrical, plumbing, mechanical, gas and energy-code inspections. Work cannot proceed past a given stage without a written release, and no certificate of occupancy issues until the final inspection passes. This is a City of Fulton County, Georgia ordinance, not the same-named Roswell, New Mexico.

Violations & Fines

Working past an uninspected stage or occupying without a certificate of occupancy can trigger a stop-work order and code enforcement action under the technical codes.

Frequently Asked Questions

Can I cover framing before it's inspected?
No. Roswell requires a written release from the chief building inspector after each successive inspection before work can be concealed.
Who performs Roswell's building inspections?
The chief building inspector or designated inspection staff, per Roswell Code of Ordinances § 5.4.39.

Sources & Official References

Other rules in Roswell

All Roswell rules

Compare Roswell to another location·View the Georgia building safety overview

Get notified when Building Inspections in Roswell, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Building Inspections in Nearby Cities

How other cities in Fulton County handle building inspections.

Atlanta, GA
Some Restrictions