Key Facts

Footing inspection
after excavation, before concrete pour
Rough inspection
before insulation, lath or gypsum board
Notice required
48 hours by phone, excluding weekends
Concrete inspection notice
2 hours, called in by 2:30 p.m.
Final inspection
after fire/alarm/suppression testing complete

Summary

Tinley Park requires the Building Official to inspect construction at defined stages before work may proceed, from footing and foundation through rough framing and insulation to a final inspection. Contractors must call the Building Department at least 48 hours ahead to schedule (two hours for concrete pours before 2:30 p.m.), and no rough framing inspection happens until electrical, plumbing and HVAC rough-ins are approved first.

SECTION 102 - INSPECTIONS A. For on site construction the Building Official upon notification from the permit holder or their agent shall make or cause to be made any necessary inspections and shall either approve that portion of the construction as completed or shall notify the permit holder or their agent wherein the same fails to comply with this Code. ... 3. Footing Inspection: Commonly made after excavations are complete and footing forms are set but prior to pouring concrete. 4. Foundation Wall: Commonly made after forms are set and braced and all reinforcing is in place and tied and all inserts are placed, but before pouring of concrete. 5. Rough Inspection: Commonly made after the roof, masonry, all framing, firestopping, and bracing are in place and all electrical, plumbing and mechanical/HVAC, chimneys, and fireplaces are complete, but prior to the installation of any insulation, lath or gypsum board. ... E. Requests for inspections shall be made to the Building Department, by telephone not less than forty-eight (48) hours (excluding Saturdays, Sundays and Holidays) before inspection is requested.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-40: Supplement contains: Local legislation current through Ordinance 2026-O-007, passed 2-17-2026, Resolution 2018-R-077, passed 10-2-18, and State legislation current through 2010 Pamphlet No. 7).

Full Breakdown

07(A)(3), lists the inspections the Building Official performs at each stage of a Tinley Park construction project. A footing inspection happens after excavation is complete and forms are set but before concrete is poured; a foundation wall inspection follows once forms are braced and reinforcing steel is tied in place, again before concrete pours. A rough inspection covers the roof, masonry, all framing, firestopping and bracing along with electrical, plumbing, mechanical and HVAC work, chimneys and fireplaces, and must happen before any insulation, lath or gypsum board goes up; the Code specifically bars a rough framing inspection until the electrical, plumbing and HVAC rough-ins are separately inspected and approved.

An insulation inspection follows the rough inspection but comes before lath or gypsum board installation, and nailing or screw-pattern checks cover lateral shear or bracing walls. Job sites must provide safe, slip-resistant access and be cleared of debris so the inspector can see all the work; ladders or level changes over 24 inches do not count as accessible. Work cannot proceed past the point covered by each successive inspection without the Building Official's written approval. or they roll to the next day. A final inspection follows completion of the building and any required fire department hydrostatic, alarm, or hood-suppression testing.

Violations & Fines

Building past an inspection point without the Building Official's written approval violates § 155.07(A)(1)J's ban on working outside the Code's terms, exposing the owner or contractor to the general misdemeanor penalty of up to $750 per day under § 155.07(A)(1)K. A Building Official who finds work does not comply with an inspected stage will refuse approval and can direct that a stop-work order be posted at the site until corrected.

Frequently Asked Questions

What inspections does Tinley Park require during construction?
The Building Official inspects at set stages: footing, foundation wall, rough (covering framing, electrical, plumbing and HVAC), insulation, and a final inspection. Rough framing cannot be approved until electrical, plumbing and HVAC rough-ins pass their own inspections, and each stage needs written approval before work moves to the next.
How much notice does Tinley Park need to schedule an inspection?
Call the Building Department at least 48 hours ahead, not counting Saturdays, Sundays or holidays. Concrete inspections are the exception: they need only two hours' notice, but the request must come in by 2:30 p.m. or it gets scheduled for the next business day.
Can I keep building before an inspection is approved in Tinley Park?
No. § 155.07(A)(3)D bars any work beyond the point covered by each inspection until the Building Official gives written approval. Proceeding anyway violates the Code's compliance requirement and can draw the standard misdemeanor fine of up to $750 per day of continued violation.

Sources & Official References

Other rules in Tinley Park

All Tinley Park rules

Compare Tinley Park to another location·View the Illinois building safety overview

Get notified when Building Inspections in Tinley Park, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.