Skip to main content
CityRuleLookup

Fremont, CA Building Safety: Plumbing Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Adopted code
2025 California Plumbing Code
Governing section
FMC 15.20.020
Appendices adopted
A, B, and D only
Permit process
follows Ch. 15.05 / Sec. 15.10.040
Seismic gas valve
required over $10,000 remodel

Summary

Fremont adopts the 2025 California Plumbing Code as the Fremont Plumbing Code under Municipal Code Section 15.20.020, with only three CPC appendices in force and a local earthquake gas shutoff valve mandate. Permit administration and enforcement for plumbing work runs through the general building permit procedures in Chapter 15.05 and Section 15.10.040.

The 2025 Edition of the California Plumbing Code (CPC) as published by the California Building Standards Commission is adopted as the plumbing code of the city of Fremont, California, as if fully set out in this chapter, and is amended as set forth in this chapter. A copy of the 2025 CPC shall be maintained on file in the office of the building official. ... Section 1211.8 Earthquake-Actuated Gas Shutoff Valves. Earthquake-actuated gas shutoff valves designed to automatically shut off the gas at the location of the valve in the event of a seismic disturbance and certified by the State Architect as conforming to California Code of Regulations, Title 24, Part 12, Chapter 12-16-1, shall be installed in all new buildings and in existing buildings that undergo alterations or additions that exceed $10,000.

View official code

Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 02-2026, passed May 5, 2026).

Full Breakdown

020 adopts the 2025 Edition of the California Plumbing Code as published by the California Building Standards Commission as the plumbing code of the city of Fremont, as if fully set out in the chapter, and directs that a copy be kept on file in the office of the building official. 030 limits which CPC appendices apply locally to Appendix A (Recommended Rules for Sizing the Water Supply System), Appendix B (Explanatory Notes on Combination Waste and Vent Systems), and Appendix D (Sizing Storm Water Drainage Systems); no other appendix is adopted.

040 of the Fremont building code for administration and enforcement, meaning a plumbing permit follows the same application, fee, expiration, and inspection rules that apply to a building permit. 050, requires an earthquake-actuated gas shutoff valve, certified by the State Architect under California Code of Regulations Title 24, Part 12, Chapter 12-16-1, on every new building and on any existing building undergoing alterations or additions exceeding $10,000 in value.

Violations & Fines

Because plumbing permits are administered under the general Fremont building code, plumbing work performed without a permit is subject to the same doubled permit fee under Section 109.4 and separate investigation fee under Section 109.4.1 that apply to unpermitted building work. Skipping the required earthquake-actuated gas shutoff valve on a qualifying new building or a remodel over $10,000 leaves the installation out of compliance with Section 15.20.050 and subject to correction before final inspection.

Frequently Asked Questions

What plumbing code does Fremont enforce?
Fremont adopted the 2025 California Plumbing Code in full under Municipal Code Section 15.20.020, calling it the Fremont Plumbing Code, and keeps a copy on file with the building official. Only Appendices A, B, and D of the CPC are locally adopted; the remaining appendices do not apply inside city limits.
Where do I apply for a plumbing permit in Fremont?
Fremont did not adopt the CPC's own administrative chapter. Section 15.20.040 instead routes plumbing permit applications through the same administration and enforcement rules used for building permits generally, found in Chapter 15.05 and Section 15.10.040, so plumbing permits share the building department's application, fee, and expiration process.
Does Fremont require an earthquake gas shutoff valve?
Yes, on some projects. Section 15.20.050 requires a State Architect-certified earthquake-actuated gas shutoff valve in every new building and in any existing building where alterations or additions exceed $10,000 in value, so the valve requirement can be triggered by a remodel even if the original building did not have one.

Sources & Official References

Other rules in Fremont

All Fremont rules

California rules heatmap·Compare Fremont to another location·View the California building safety overview

Get notified when Plumbing Permits in Fremont, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Plumbing Permits in Nearby Cities

How other cities in Alameda County handle plumbing permits.

Oakland, CA
Some Restrictions
Livermore, CA
Some Restrictions
Berkeley, CA
Some Restrictions
Hayward, CA
Some Restrictions