Key Facts

District
Residential Charter Neighborhood (RCN)
Front setback
average of adjacent lots
No houses on block
defaults to 25 feet
Corner commercial
0-foot front setback allowed

Summary

In Pueblo's Residential Charter Neighborhood (RCN) District, the front yard setback isn't a fixed number -- it matches the average of existing building setbacks on the block.

The front yard setback for all buildings, except commercial buildings on a corner lot, shall be the average of the existing building setbacks on adjacent lots. If there is only one (1) adjacent lot with a building, the setback shall be equal to its setback. If both adjacent lots are vacant, the setback shall be the average of all existing building setbacks on the block. If there are no houses on the block, the setback shall be twenty-five (25) feet.

b. The minimum front yard setback for commercial buildings on a corner lot is zero (0) feet.

(4) Side yard setbacks shall be as follows:

a. Lot width of thirty-five (35) feet or fewer:

1. Side yard setbacks for one- and two-family residential units and their accessory structures on lots thirty-five (35) feet or fewer in width shall be three (3) feet. Projections shall not extend to a point closer than two (2) feet from the property line.

2. Other buildings: five (5) feet.

3. Two (2) one-family residences may be constructed on two (2) separate parcels, connected to each other (zero setbacks) on one (1) side with a side yard setback of five (5) feet on the other side, provided that the residences are built at the same time.

b. Side yard setbacks for lots greater than thirty-six (36) feet in width: five (5) feet.

(5) Performance standards.

a. Not more than fifty percent (50%) of the front yard setback shall be covered with an impervious surface.

b.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 109).

Full Breakdown

Section 17-4-4(f)(3)a sets Pueblo's RCN District front yard setback contextually rather than as a flat distance: it equals the average setback of adjacent lots, or if only one adjacent lot has a building, it matches that building's setback; if both adjacent lots are vacant, it's the average for the whole block; and if the block has no houses at all, the setback defaults to twenty-five feet. Commercial buildings on corner lots get a zero-foot minimum front setback under 17-4-4(f)(3)b, and the Zoning Administrator can approve reductions with documented survey evidence of the existing block pattern.

Violations & Fines

Building closer to the street than the calculated setback without Zoning Administrator approval is a zoning code violation, enforced through Pueblo's building permit and zoning review process.

Frequently Asked Questions

How is the front yard setback measured in Pueblo's RCN District?
It's the average of existing building setbacks on the adjacent lots, not a fixed number, per Pueblo Municipal Code Section 17-4-4(f)(3)a.
What if there are no other houses on the block yet?
The Code defaults to a twenty-five-foot front yard setback when the block has no existing houses to average from.

Sources & Official References

Other rules in Pueblo

All Pueblo rules

Compare Pueblo to another location·View the Colorado building setbacks & zoning overview

Get notified when Setback Rules in Pueblo, CO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.