Gardena, CA Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- R-1 max height
- 25 feet
- Max stories
- 2 stories
- Attached ADU above garage
- May match 25 ft primary-home limit
- Detached ADU height
- 16 to 18 feet, lower than main house
- Last amended
- Ordinance 1873 § 1, 2024
Summary
A single-family house in Gardena's R-1 zone cannot rise above twenty-five feet or more than two stories. Section 18.12.050(F) sets that flat height ceiling for the R-1 zone, and it applies to the whole building envelope, main house included, alongside the zone's separate five-thousand-square-foot minimum lot size and eight-hundred-square-foot minimum dwelling size.
F. Building Height. The maximum building height shall not exceed twenty-five feet and shall consist of not more than two stories;
Full Breakdown
Section 18.12.050 of the Gardena Municipal Code lists the property development standards that apply to every lot and building in the R-1 single-family residential zone, and subsection F states the height limit directly: the maximum building height shall not exceed twenty-five feet and shall consist of not more than two stories. That twenty-five-foot, two-story ceiling governs the primary dwelling on an R-1 lot; an attached accessory dwelling unit built above an existing garage may match that twenty-five-foot limit under Section 18.13.050(G)(4), but a detached accessory dwelling unit is instead capped at sixteen to eighteen feet under that same section.
The height standard sits alongside the zone's other numeric limits in Section 18.12.050: a minimum five-thousand-square-foot lot area, minimum fifty-foot lot width for interior lots and fifty-five feet for corner lots, a minimum eighty-foot lot depth, and a minimum eight-hundred-square-foot dwelling unit excluding the garage. Section 18.12.050(L) folds in the general provisions table found in Section 18.42.010 for any standard not separately stated here. The height limit was most recently amended by Ordinance 1873, section 1, adopted in 2024, part of a broader package of R-1 development standard revisions in Section 18.12.050 that also touched the accessory building setback and lot coverage rules in that same section.
Uses not listed as permitted or conditionally permitted in Sections 18.12.020 and 18.12.030 are expressly prohibited in the R-1 zone under Section 18.12.040, and any structure exceeding the height standard without a variance falls into that prohibited-use category.
Violations & Fines
Constructing or altering a house above the twenty-five-foot, two-story limit in Section 18.12.050(F) without an approved variance is a code violation under Section 1.16.010, a misdemeanor carrying up to a $1,000 fine and up to six months in jail, or an infraction at the city attorney's discretion with fines of $100, $200 and $500 for repeat violations in a year. Community Development can red-tag work exceeding the approved height and require a variance application to the planning commission before construction continues.
Frequently Asked Questions
How tall can I build a house in Gardena's R-1 zone?
Does the height limit differ for a detached accessory dwelling unit?
Can I get a variance to build taller than twenty-five feet?
Sources & Official References
Other rules in Gardena
California rules heatmap·Compare Gardena to another location·View the California building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Structure Height Limits in Nearby Cities