Skip to main content
CityRuleLookup

Plantation, FL Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified July 2026

Key Facts

RS districts
35 feet maximum
RS-1EP rural estate
40 feet maximum
Above 27 feet in RS-1EP
1.5 feet extra setback per foot
Exempt features
Cupolas, steeples, chimneys, antennas, flagpoles
Source
Sec. 27-72, Tables 72-2 and 72-4

Summary

Every standard RS single-family district in Plantation caps buildings at thirty-five feet under Table 72-4. The RS-1EP rural estate district allows forty feet, but anything above twenty-seven feet there needs deeper side and rear setbacks.

Any building or structure that exceeds twenty-seven (27) feet in height shall be subject to an increased side and rear yard setback requirement. The side and rear yard setbacks shall be increased by one and one-half (1.5 feet for each foot or portion thereof of the building or structure that exceeds twenty-seven (27) feet in height with the height of the building or structure being measured from the property's average grade to the highest point of the building or structure).

Source: City of Plantation Code of Ordinances (Municode)View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 30 Update 1).

Full Breakdown

Section 27-72 carries the dimensional standards. Table 72-4 covers RS-1A through RS-5K and sets a thirty-five-foot maximum height in every one of them. Table 72-2 governs the RS-1EP rural estate district, where the maximum is forty feet; any building or structure exceeding twenty-seven feet there takes an increased side and rear setback of one and one-half feet for each foot above twenty-seven, measured from average grade to the highest point. Section 27-296(n) lets scenery lofts, towers, cupolas, steeples, domes, flagpoles, antennas, chimneys, stacks, tanks and rooftop gardens exceed the district limit.

Violations & Fines

Exceeding the district maximum is a code violation the city can take to the code enforcement board, where a fine may run to one thousand dollars per day for a first violation and five thousand for a repeat.

Frequently Asked Questions

How tall can I build a house in Plantation?
Thirty-five feet in the standard RS single-family districts under Table 72-4, and forty feet in the RS-1EP rural estate district under Table 72-2.
Do chimneys and antennas count toward the height limit?
No. Section 27-296(n) lets cupolas, steeples, domes, flagpoles, antennas, chimneys, stacks, tanks and rooftop gardens exceed the permissible height limit in any district.

Sources & Official References

Other rules in Plantation

All Plantation rules

Florida rules heatmap·Compare Plantation to another location·View the Florida building setbacks & zoning overview

Get notified when Structure Height Limits in Plantation, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Nearby Cities

How other cities in Broward County handle structure height limits.

Hollywood, FL
Some Restrictions
Pembroke Pines, FL
Some Restrictions
Miramar, FL
Some Restrictions
Pompano Beach, FL
Some Restrictions