Tinley Park, IL Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Max garage footprint
720 sq ft (one-story frame)
Max garage height
18 ft at roof peak, pitched roof
Interior fire separation
1/2-inch gypsum if under 10 ft from house
Applies to
detached, one-story frame garages only
Principal structure height
set by separate Zoning Ordinance

Summary

Tinley Park's Building Code caps detached, one-story frame garages at 720 square feet and 18 feet of height at the roof peak, measured from the finished floor to the top of a pitched roof. Attached garages instead follow the same construction rules as the house itself. Height limits for the principal dwelling sit in the separate Zoning Ordinance, not this section.

SECTION 309.6 - SINGLE FAMILY DETACHED GARAGES: A. One-story frame detached garages. 1. Maximum size cannot exceed 720 square feet. 2. Total height of a pitched roof garage shall not exceed eighteen (18) feet at the roof peak when measured from the finished floor.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-40: Supplement contains: Local legislation current through Ordinance 2026-O-007, passed 2-17-2026, Resolution 2018-R-077, passed 10-2-18, and State legislation current through 2010 Pamphlet No. 7).

Full Breakdown

07(B)(5), sets specific construction standards for one-story frame detached garages in Tinley Park. The maximum footprint is 720 square feet, and where the garage has a pitched roof, the total height cannot exceed 18 feet measured from the finished floor to the roof peak. The same subsection requires the garage to follow one-story dwelling construction standards from the International Residential Code, with village-specific exceptions covering grade-beam foundations, minimum stud spacing of 24 inches on center with solid mid-height blocking, wall sheathing thickness, rafter design for 30 psf snow loading, and a ban on gas-fired appliances unless AGA-approved and vented with a sealed combustion chamber.

A separate provision in the same chapter sends applicants to the Tinley Park Zoning Ordinance for the required setback and separation distance from the primary structure, and if a detached garage sits less than 10 feet from the house it needs a minimum half-inch gypsum board (or equivalent) on the interior for fire separation. One-story solid masonry or masonry-veneer detached garages follow the same one-story dwelling standards but with their own footing and foundation specifications: a spread footing at least 10 inches deep and 20 inches wide, bottom of footing at least 3 feet 6 inches below finished grade, and foundation walls at least 8 inches thick.

None of this touches the height allowed for the house itself or other principal structures, which the Building Code leaves to the village's separate Zoning Ordinance.

Violations & Fines

Building a detached garage taller than 18 feet at the roof peak, or larger than 720 square feet, without a variance is unlawful construction under § 155.07(A)(1)J. Violators face the Building Code's general misdemeanor penalty of up to $750 for each day the noncompliant structure remains, and the Building Official can refuse a Certificate of Occupancy or order the excess brought into compliance.

Frequently Asked Questions

How tall can a detached garage be in Tinley Park?
A one-story frame detached garage with a pitched roof cannot exceed 18 feet measured from the finished floor to the roof peak, under § 155.07(B)(5)'s Section 309.6. The same subsection caps the footprint at 720 square feet for a one-story frame garage.
Does Tinley Park's building code set the height limit for my house?
No. The Building Code's Section 309.6 height cap applies only to detached, one-story frame garages. Height limits for the principal dwelling and other structures come from the village's separate Zoning Ordinance, which the Building Code cross-references rather than restates.
How close can a detached garage sit to my house in Tinley Park?
The Building Code sends you to the Zoning Ordinance for the required setback and separation distance from the primary structure, but if the garage ends up less than 10 feet away, § 155.07(B)(5) requires at least half-inch gypsum board on the interior wall for fire separation.

Sources & Official References

Other rules in Tinley Park

All Tinley Park rules

Compare Tinley Park to another location·View the Illinois building setbacks & zoning overview

Get notified when Structure Height Limits in Tinley Park, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Nearby Cities

How other cities in Cook County handle structure height limits.

Chicago, IL
Some Restrictions
Arlington Heights, IL
Some Restrictions
Evanston, IL
Some Restrictions
Skokie, IL
Some Restrictions
Schaumburg, IL
Some Restrictions
Oak Lawn, IL
Some Restrictions