Skip to main content
CityRuleLookup

Building Safety in Chino, CA (2026)

7 verified building safety rules for Chino, California, sourced directly from the municipal code and official government pages.

Verified from official government sources

Fire Sprinkler Requirements

Chino requires automatic fire sprinklers in new buildings of 5,000 square feet or more, but its local amendment expressly excludes one- and two-family homes and their accessory structures.

Chino Building Fire Sprinkler Rule

Some Restrictions

Chino Municipal Code § 15.04.050 (CBC § 903.2 as amended)

In addition to the requirements of Section 903, fire sprinklers are required for the construction of buildings five thousand square feet or more, regardless of fire walls, except for Group R-3 (one- and two-family dwelling) and Group U accessory to Group R-3 occupancies. Fire sprinklers are required when additions exceed five thousand square feet. When the addition is less than fifty percent...

Childcare Center Rules

Chino requires child day care centers to fence pools at five feet non-climbable, fence outside play areas at five feet, and keep play areas ten feet from public rights-of-way.

Chino Child Day Care Center Safety Rules

Some Restrictions

Chino Municipal Code § 20.21.090(C)(3), (E)(3)-(5)

C.General standards that apply to all child day care facilities.3.Any swimming pool, pond, wading pools, or similar bodies of water greater than eighteen inches in depth shall be fully enclosed by a minimum five-foot-high non-climbable fence...E.Child day care centers.3.Outside play areas shall have a minimum fence height of five feet.4.Outside play areas shall be located a minimum of ten feet ...

Door Locking Hardware

New residential buildings in Chino must use solid-core exterior doors with one-inch deadbolt locks equipped with steel inserts and free-turning cylinder guards, under the city's security and safety standards for construction.

Chino Door Locking Hardware Rules

Some Restrictions

Chino Municipal Code § 15.48.070(A)

A.Doors shall comply with the following regulations:1.All exterior swinging doors shall be of solid core construction with a minimum thickness of one and three-fourths inches, or with panels not less than nine-sixteenths inch thick.2.Any swinging door leading from a garage into a residence, shall be of solid core construction with a minimum thickness of one and three-eighths inches.3.All swingi...

Building Permits

Chino requires a building permit for construction and alteration work unless the work falls into a specific, narrow list of exemptions set out in the city's amended Building Code.

Chino Building Permit Exemptions

Some Restrictions

Chino Municipal Code § 15.04.180

105.2 Work exempt from permit. A building permit will not be required for the following: 1.One story detached accessory structures used as tool and storage sheds, gazebos, playhouses, temporary tents, and similar uses, provided the floor area does not exceed one hundred twenty square feet and has all the required yards. ... Unless otherwise exempted by this code, separate plumbing, electrical, ...

Electrical Permits

Chino has adopted the 2022 California Electrical Code, incorporating the 2020 National Electrical Code, to regulate wiring and electrical installations citywide, with permit fees set by city council resolution.

Chino Electrical Permit & Code Rules

Some Restrictions

Chino Municipal Code § 15.28.010 - Adopted.

There is adopted by reference the 2022 California Electrical Code, incorporating the 2020 National Electrical Code. ... is adopted as the Electric Code of the city of Chino for regulating the installation, maintenance and repair of electrical wiring and equipment within the city and prescribing standards of inspection and requirements therefor.

Plumbing Permits

Chino has adopted the 2022 California Plumbing Code, incorporating the 2021 Uniform Plumbing Code, to govern plumbing installation, maintenance, and repair citywide, with permit fees set by city council resolution.

Chino Plumbing Permit & Code Rules

Some Restrictions

Chino Municipal Code § 15.24.010 - Adopted.

There is adopted by reference the 2022 California Plumbing Code, incorporating the 2021 Uniform Plumbing Code, including Chapter 1, Division II. That certain document, three copies of which are on file with the city of Chino, being designated and marked as the California Plumbing Code, copyrighted 2021 by the International Association of Plumbing and Mechanical Officials, is adopted for regulat...

Building Inspections

Chino's building official posts color-coded safety assessment placards after inspecting damaged buildings: green for lawful occupancy, yellow for restricted use, and red barring entry until repairs are made.

Chino Building Safety Assessment Placards

Some Restrictions

Chino Municipal Code § 15.60.040

This chapter approves the use of standard placards to indicate the condition of buildings and structures for continued occupancy...The term "safety assessment" shall mean a visual, non-destructive examination of a building or structure by the building official...for the purpose of determining its suitability for continued occupancy. INSPECTED—Lawful Occupancy Permitted. This placard is to be po...

Looking for San Bernardino County county-wide rules?

County ordinances apply to unincorporated areas and may supplement Chino city rules.

Building Safety in San Bernardino County