Building Setbacks & Zoning in Pageland, SC (2026)
2 verified building setbacks & zoning rules for Pageland, South Carolina, sourced directly from the municipal code and official government pages.
Verified from official government sources
Setback Rules
Pageland's Table 2 sets front setbacks from zero feet downtown to 50 feet in the general commercial and industrial districts, with residential side and rear yards generally 10 to 15 feet. Section 8-2 lets corner lots and multi-building sites vary these minimums.
Pageland Zoning Setback Minimums
Some RestrictionsPageland Town Code App. A, § 3-2, Table 2
R-8 R-6 GR GRR RC NC CC GC LI BI ... Minimum Yard & Building Setback (ft.) (A) Front 20 15 15 15 15 25 0 50 50 50 Side Residential 10 10 E E 10 NA NA 10 NA NA Non-Residential 50 40 40 40 40 10 0 10 50 50 Rear Residential 15 F 15 15 15 NA NA 25 NA NA Non-Residential 30 25 25 25 25 15 0 25 50 50
Structure Height Limits
Pageland caps building height at 35 feet in its lowest-density residential and commercial districts and 60 feet in GR, GRR, CC, GC and both industrial zones. Height is measured from average finished grade to the roof's highest point, with listed exceptions like church spires and water tanks.
Pageland Zoning Building Height Limits
Some RestrictionsPageland Town Code App. A, § 3-2, Table 2
R-8 R-6 GR GRR RC NC CC GC LI BI ... Maximum Height (ft.) (C) 35 35 60 60 35 35 60 60 60 60 ... C - Measurement from average elevation of the finished grade at the building line to the highest point on the roof.