Key Facts

Code
Dev. Code Sec. 9.210.060
Exterior day
65 Leq, 7 a.m.-10 p.m.
Exterior night
45 Leq, 10 p.m.-7 a.m.
Interior
55 day / 40 night
HVAC
Exempt if in proper repair

Summary

Menifee caps stationary-source noise at another occupied property at 65 Leq exterior from 7 a.m. to 10 p.m. and 45 Leq overnight, under Development Code Table 9.210.060-1. Heating and air conditioning equipment in proper repair is exempt.

No person shall create any sound, or allow the creation of any sound, on any property that causes the exterior and interior sound level on any other occupied property to exceed the sound level standards set forth in Table 9.210.060-1, Stationary Source Noise Standards.

Source: Menifee Development Code (Municipal Code Title 9), Articles 3 and 4View official code

Full Breakdown

Section 9.210.060 of the Menifee Development Code sets citywide stationary source noise standards. No person may create sound that causes exterior levels on another occupied property to exceed 65 Leq (10-minute) between 7 a.m. and 10 p.m. or 45 Leq (10-minute) between 10 p.m. and 7 a.m. Interior standards are 55 Leq day and 40 Leq night. Measurements are taken anywhere within the boundaries of the occupied receiving property using a calibrated sound level meter. Like Riverside County, Menifee exempts heating and air conditioning equipment in proper repair, which covers much of a data center's cooling load. Backup generators and other plant equipment remain subject to the table.

Violations & Fines

Sound above the Table 9.210.060-1 limits is a Development Code violation enforced by peace officers and code enforcement officers; refusing to cooperate with an officer measuring the sound is a separate violation.

Frequently Asked Questions

How loud can a data center be in Menifee?
Exterior noise at another occupied property must stay at or below 65 Leq (10-minute) daytime and 45 Leq overnight under Development Code Table 9.210.060-1.
Does Menifee regulate data-center cooling noise?
No. Section 9.210.060.B exempts heating and air conditioning equipment in proper repair, matching Riverside County. Generators and other equipment still fall under the table limits.

Sources & Official References

Other rules in Menifee

All Menifee rules

California rules heatmap·Compare Menifee to another location·View the California data centers & crypto mining overview

Get notified when Data Center Noise Limits in Menifee, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Data Center Noise Limits in Nearby Cities

How other cities in Riverside County handle data center noise limits.

Corona, CA
Light Restrictions
Palm Springs, CA
Some Restrictions
Moreno Valley, CA
Some Restrictions
Murrieta, CA
Some Restrictions
Jurupa Valley, CA
Some Restrictions
Riverside, CA
Some Restrictions
Temecula, CA
Significant Restrictions