Skip to main content
CityRuleLookup

Akron, OH Environmental Rules: Flood Elevation Requirements (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential elevation standard
Lowest floor at or above base flood elevation
Nonresidential alternative
Certified floodproofing to base flood level
Accessory-structure variance cap
576 sq ft, built for under $7,000
Verification required
Surveyor's elevation letter before occupancy
Manufactured homes
Must sit on permanent foundation at BFE
Default penalty
Up to $150 per offense, § 10.99

Summary

Akron requires new and substantially improved homes in mapped flood zones to have their lowest floor, including basement, built at or above the base flood elevation. Nonresidential buildings can floodproof instead of elevate if a licensed engineer certifies the work.

A.Residential Construction.1.New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to or above the base flood elevation.B.Nonresidential Construction.1.New construction and substantial improvement of any commercial, industrial, or other nonresidential structure shall either have the lowest floor, including basement, elevated to the level of the base flood elevation, or, together with attendant utility and sanitary facilities, shall: a.Be floodproofed so that, below the base flood level, the structure is watertight with walls substantially impermeable to the passage of water

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 64).

Full Breakdown

315(A) requires that new construction and substantial improvement of any residential structure have its lowest floor, including the basement, elevated to or above the base flood elevation, the FEMA-mapped level with a one-percent annual chance of being equaled or exceeded. 315(B) gives nonresidential buildings, such as commercial or industrial structures, a choice: elevate the lowest floor to the base flood elevation, or floodproof the structure so it is watertight below that level with walls substantially impermeable to water and components able to resist hydrostatic and hydrodynamic loads, certified by a registered professional engineer or architect.

318. 314(A) and elevated on a permanent foundation so the lowest floor sits at or above the base flood elevation; the same standard reaches recreational vehicles sited for 180 days or more or that are not fully licensed and ready for highway use. 309 requires the applicant to submit a surveyor's letter before final occupancy certifying the actual elevation of the lowest habitable floor, and a footing-elevation certification before the required footing inspection, tying the freeboard rule to actual construction verification rather than the submitted plans alone.

Violations & Fines

Constructing or substantially improving a structure below the required base flood elevation without the § 197.312 variance is a building code violation enforced by the Superintendent of Building Inspection, who reviews the surveyor's post-construction elevation certification required under § 197.309. Chapter 197 sets no elevation-specific fine, so the citywide default in § 10.99 applies: up to $150 per offense absent a more specific penalty, with each day of an uncorrected violation a separate offense. Any owner granted a variance below base flood elevation must receive written notice that flood insurance costs will reflect the increased risk.

Frequently Asked Questions

How high above the flood level must a new Akron house be built?
Section 197.315(A) requires the lowest floor, including any basement, of new construction or a substantial improvement to a residential structure to be elevated to or above the base flood elevation, the FEMA-designated one-percent annual chance flood level.
Can a commercial building in Akron floodproof instead of elevating?
Yes. Section 197.315(B) allows nonresidential structures to be floodproofed watertight below the base flood elevation instead of elevated, but a registered professional engineer or architect must certify that the floodproofing meets the chapter's structural standards.
Is there any exception to Akron's base flood elevation rule for small structures?
Section 197.315(B)(2) allows a variance for accessory structures like sheds or detached garages under 576 square feet built for less than $7,000, provided they are not used for habitation, are anchored against flotation, and meet the floodway and opening requirements elsewhere in the chapter.

Sources & Official References

Other rules in Akron

All Akron rules

Compare Akron to another location·View the Ohio environmental rules overview

Get notified when Flood Elevation Requirements in Akron, OH changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.