Ankeny, IA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential floor elevation
1 ft above base flood elevation
Non-residential floor/floodproofing
1 ft above base flood elevation
Flood control works freeboard
3 ft above base flood
Fill extension required
18 ft beyond structure
Small accessory exemption
detached structures under 600 sq ft

Summary

In the City of Ankeny, Iowa, new and substantially improved homes in the mapped flood plain must have their lowest floor, including any basement, at least one foot above the base flood elevation, built on compacted fill extending 18 feet beyond the structure. Flood control works like levees and flood walls must carry three feet of design freeboard above the base flood.

Residential structures - All new or substantially improved residential structures shall have the lowest floor, including basements, elevated a minimum of one foot above the base flood elevation. Construction shall be upon compacted fill which shall, at all points, be no lower than one foot above the base flood elevation, and extend at such elevation at least 18 feet beyond the limits of any structure erected thereon. ... Flood control structural works such as levees, flood walls, etc. shall provide, at a minimum, protection from the base flood with a minimum of three feet of design freeboard, and shall provide for adequate interior drainage.

Full Breakdown

Ankeny Code of Ordinances § 193.01(11)(B)(2)(b) sets the elevation standard for residential construction in the Floodway Fringe (Overlay) Subdistrict: new or substantially improved residential structures must have the lowest floor, including basements, elevated a minimum of one foot above the base flood elevation, built on compacted fill that stays at or above that one-foot elevation at every point and extends at least 18 feet beyond the structure's limits. Piers or extended foundations may substitute for fill only with a conditional use permit from the Board of Adjustment where topography or street grades preclude filling.

Section 193.01(11)(B)(2)(c) applies the same one-foot floor elevation to non-residential buildings, or allows floodproofing certified by an Iowa-registered professional engineer to that level. Sections 193.01(11)(B)(2)(f) and (g) extend the one-foot elevation requirement to electric meters, service panels, water heaters, HVAC equipment, plumbing, gas lines and water and gas meters. Separately, § 193.01(11)(B)(2)(o) requires flood control structural works such as levees and flood walls to provide, at a minimum, protection from the base flood with three feet of design freeboard, plus adequate interior drainage, and any such structural works must be approved by the Iowa Department of Natural Resources.

Detached garages and sheds under 600 square feet are exempt from the one-foot elevation rule under § 193.01(11)(B)(2)(s) if built of flood-resistant material below that line, not used for habitation, anchored against flotation, and vented per the code's opening requirements.

Violations & Fines

Building below the required elevation, or altering fill, floor height or floodproofing from what an approved flood plain development permit shows, is a violation punishable as a municipal infraction under § 193.01(21), carrying the civil penalty set in Chapter 4 of the Ankeny Municipal Code. The Zoning Administrator can require a professional engineer's certification of the as-built elevation before occupancy.

Frequently Asked Questions

How high above the base flood elevation must a new Ankeny home be built?
Under § 193.01(11)(B)(2)(b), the lowest floor, including any basement, must sit at least one foot above the base flood elevation, resting on compacted fill that holds that elevation at every point and reaches at least 18 feet beyond the structure.
Is there a freeboard requirement for levees or flood walls in Ankeny?
Yes. Section 193.01(11)(B)(2)(o) requires flood control structural works such as levees and flood walls to provide at least three feet of design freeboard above the base flood, plus adequate interior drainage, and the Iowa DNR must approve the structural design.
Can a shed or detached garage skip the flood elevation rule in Ankeny?
Yes, under § 193.01(11)(B)(2)(s), if it is 600 square feet or less, built of flood-resistant material below the one-foot line, not used for habitation, anchored against flotation, and vented to equalize floodwater pressure.

Sources & Official References

Other rules in Ankeny

All Ankeny rules

Compare Ankeny to another location·View the Iowa environmental rules overview

Get notified when Flood Elevation Requirements in Ankeny, IA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.