Skip to main content
CityRuleLookup

Casper, WY Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard requirement
One foot above base flood elevation
Applies to
New and substantially improved residential structures
Certification required
Registered engineer, architect, or land surveyor
Enclosure venting
1 sq in per sq ft, openings within 1 ft of grade
Recreational vehicle exemption
On site fewer than 180 consecutive days

Summary

In the City of Casper, new and substantially improved residential structures inside a mapped flood hazard area must have their lowest floor built at least one foot above the base flood elevation. Casper Municipal Code section 17.20.100(A)(1) sets that freeboard requirement and requires a registered professional's elevation certification before the floodplain administrator signs off.

1.Residential Construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated no less than one foot above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in Section 17.20.070(A)(1), is satisfied.

Full Breakdown

Section 17.20.100(A) of the Casper Municipal Code sets the specific construction standards that apply once base flood elevation data exists for a site under section 17.20.040(B), 17.20.060(A)(8), or 17.20.110(C). Subsection (A)(1) governs residential construction: any new home or substantially improved residential structure must have its lowest floor, including any basement, elevated no less than one foot above the base flood elevation, and a registered professional engineer, architect, or land surveyor must certify to the floodplain administrator that the elevation meets that standard. Nonresidential buildings get an alternative under subsection (A)(2): they can meet the same one-foot freeboard or instead be floodproofed watertight below that level, certified by a licensed engineer or architect who documents the specific floodproofed elevation for the administrator's records.

Subsection (A)(3) covers enclosed areas below the lowest floor used only for parking, building access, or storage: they need at least two flood openings totaling one square inch of net area per square foot of enclosed floor space, with the bottom of each opening no higher than one foot above grade, so floodwater can enter and exit without building up hydrostatic pressure on the walls. Manufactured homes placed in a mapped zone must be elevated on a permanent foundation so the lowest floor sits at least one foot above the base flood elevation and anchored against flotation and lateral movement, per subsection (A)(4).

Recreational vehicles are exempt from the elevation standard only if they stay on site fewer than one hundred eighty consecutive days, remain licensed and ready for highway use, or meet the same permitting and elevation requirements as manufactured homes.

Violations & Fines

Building or substantially improving a residential structure below the one-foot freeboard set in section 17.20.100(A)(1) without the required elevation certification is a violation of Chapter 17.20 and Title 17's zoning enforcement provisions. It can void FEMA flood insurance eligibility, and the floodplain administrator can deny the certificate of occupancy until a licensed engineer, architect, or land surveyor documents compliance.

Frequently Asked Questions

How high above the flood line must a Casper home be built?
At least one foot above the base flood elevation, measured to the lowest floor including any basement, under Casper Municipal Code section 17.20.100(A)(1). A registered professional engineer, architect, or land surveyor has to certify that elevation to the floodplain administrator before the standard is considered satisfied.
What if I want to enclose the space under an elevated Casper home?
Section 17.20.100(A)(3) allows enclosed space below the lowest floor only for parking, building access, or storage, and it must include at least two openings totaling one square inch of net area for every square foot enclosed, with the bottom of each opening no higher than one foot above grade.
Are manufactured homes held to the same one-foot elevation rule in Casper?
Yes. Section 17.20.100(A)(4) requires manufactured homes placed in a mapped flood zone to sit on a permanent foundation elevated so the lowest floor is at least one foot above the base flood elevation, anchored to resist flotation and lateral movement during a flood.

Sources & Official References

Other rules in Casper

All Casper rules

Compare Casper to another location·View the Wyoming environmental rules overview

Get notified when Flood Elevation Requirements in Casper, WY changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.