Eden Prairie, MN Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Enforcing official
City Engineer
Freeboard required
1 foot above regional flood
Fill extension
15 feet beyond structure
Residential basements below RFPE
Prohibited
Penalty
Misdemeanor

Summary

In the City of Eden Prairie, new construction and additions inside the Floodway, Flood Fringe or General Floodplain Districts must have their lowest floor built at or above the Regulatory Flood Protection Elevation, a one-foot freeboard above the regional (100-year) flood level, verified by the City Engineer before a permit closes.

Regulatory Flood Protection Elevation (RFPE) means an elevation not less than one (1) foot above the elevation of the regional flood plus any increases in flood elevation caused by encroachments on the floodplain that result from designation of a floodway. ... All structures, including accessory structures, must be elevated on fill so that the lowest floor, as defined, is at or above the regulatory flood protection elevation. The finished fill elevation for structures must be no lower than one (1) foot below the regulatory flood protection elevation and the fill must extend at the same elevation at least fifteen (15) feet beyond the outside limits of the structure. ... Every person who violates the provisions of this section or fails to comply with any of its requirements (including violations of conditions and safeguards established in connection with grants of variances or conditional use permits) is guilty of a misdemeanor and will be punished as permitted by law.

Full Breakdown

Section 11.45 sets the Regulatory Flood Protection Elevation (RFPE) at not less than one foot above the elevation of the regional flood, adjusted for any floodway encroachments (Subd. 3, Definitions). In the Flood Fringe District, Subd. 6.B.1 requires that all structures, including accessory structures, be elevated on fill so the lowest floor sits at or above the RFPE, with finished fill no lower than one foot below the RFPE and extending at least fifteen feet beyond the structure's outside limits. Non-residential basements below the RFPE must be dry floodproofed to FP1 or FP2 State Building Code standards (Subd.

6.D.3), while residential basements below the RFPE are barred outright (Subd. 6.D.2.a). A Land Alteration or Building Permit from the City Engineer is required before any erection, addition, or fill placement in a floodplain district (Subd. 11.B.1), and on completion the permit holder must submit certification from a registered engineer, architect or land surveyor confirming the finished fill and building elevations comply (Subd. 11.B.4). Variances follow Minn. Stat. § 462.357 and City Code § 11.76 and cannot permit a lower degree of flood protection than the RFPE; the City Engineer must warn any variance applicant that building below the base flood level raises flood insurance premiums by as much as $25 per $100 of coverage (Subd. 11.C.4). The City Engineer keeps a permanent record of the lowest-floor elevation of every new or altered structure in the floodplain (Subd. 11.B.5).

Violations & Fines

Section 11.45, Subd. 13.A makes every violation of the floodplain regulations, including breach of a variance or conditional-use condition, a misdemeanor punishable as permitted by law. Each additional day a responsible party fails to respond to the City Engineer's corrective notice is a separate violation. The City may also pursue injunctions, after-the-fact permits, corrective-work orders, or ask FEMA to deny flood insurance to the violating property (Subd. 13.B-C).

Frequently Asked Questions

What is Eden Prairie's Regulatory Flood Protection Elevation?
It is at least one foot above the elevation of the regional (100-year) flood, plus any rise caused by floodway encroachments, as defined in City Code § 11.45, Subd. 3. All new floodplain structures must have their lowest floor at or above this elevation.
Can I build a basement in Eden Prairie's Flood Fringe District?
A residential basement is not allowed below the Regulatory Flood Protection Elevation. A non-residential basement may go below it only if dry floodproofed to the FP1 or FP2 State Building Code classification and certified by a registered engineer or architect.
Who verifies my home meets Eden Prairie's flood elevation rule?
The City Engineer administers § 11.45 and requires a permit before construction; on completion you must submit certification from a registered professional engineer, architect, or land surveyor that the finished fill and building elevations comply with the section.

Sources & Official References

Other rules in Eden Prairie

All Eden Prairie rules

Compare Eden Prairie to another location·View the Minnesota environmental rules overview

Get notified when Flood Elevation Requirements in Eden Prairie, MN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Hennepin County handle flood elevation requirements.

Minneapolis, MN
Some Restrictions