Key Facts
- Freeboard requirement
- BFE plus 2 feet (§ 31-7(20))
- FIS basis
- Sept. 19, 2007 Frederick County study
- Electrical panel height
- 3 feet above BFE (§ 31-19)
- Basements
- Fully below-grade basements banned
- Critical facilities
- BFE + freeboard + 1 ft, or 500-yr level
- Penalty
- Up to $1,000/day municipal infraction
Summary
New and substantially improved homes in Frederick's flood hazard areas must have their lowest floor built at or above the 'flood protection elevation,' which City Code § 31-7 defines as the base flood elevation plus two feet of freeboard. Fully below-grade basements are banned outright under § 31-31.
(20)Flood protection elevation means the base flood elevation plus 2 feet of freeboard....(b)Elevation requirements.(1)Lowest floors shall be elevated to or above the flood protection elevation.(2)In areas of shallow flooding (Zone AO), the lowest floor (including basement) shall be elevated at least as high above the highest adjacent grade as the depth number specified in feet on the FIRM plus 2 feet, or at least 4 feet if a depth number is not specified.(4)Basement floors that are below grade on all sides are prohibited.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Land Management Code: Supplement 13 | Code of Ordinances: Supplement 112).
Full Breakdown
Frederick calculates its base flood elevations from the Flood Insurance Study for Frederick County, Maryland dated September 19, 2007, and the accompanying FEMA Flood Insurance Rate Maps, kept on file at the City's Engineering Division at 140 W. Patrick Street, per § 31-3. City Code § 31-7(20) defines 'flood protection elevation' as the base flood elevation plus 2 feet of freeboard, the extra safety margin every elevated structure must clear. Under § 31-31(b), new residential structures and residential portions of mixed-use buildings must have their lowest floor, including any basement, built at or above that flood protection elevation; in Zone AO shallow-flooding areas, the floor instead must sit above the highest adjacent grade by the FIRM's depth number plus 2 feet, or at least 4 feet if no depth number is listed.
Basement floors that sit below grade on every side are prohibited outright, whether the structure is residential or nonresidential under §§ 31-31(a) and 31-32(c). Nonresidential buildings that are floodproofed instead of elevated must be watertight to the flood protection elevation plus an additional foot under § 31-32(d). Section 31-19(b)(5) separately requires the electric panelboard in any structure located in a special flood hazard area to sit at least 3 feet above the base flood elevation. 2% annual chance) flood elevation, whichever is highest.
Violations & Fines
Building below the required elevation without City Engineer approval is a Chapter 31 violation, punishable as a municipal infraction with a fine of up to $1,000 under § 31-44, with each day counted as a separate offense. Even where the Floodplain Review Board grants a variance to build below the flood protection elevation, § 31-37(e) requires written notice that federal flood insurance on the property will cost up to $25 per $100 of coverage.
Frequently Asked Questions
How high above flood level must a Frederick home be built?
Can I have a basement in a Frederick flood zone?
What happens if I build below the required flood elevation in Frederick?
Sources & Official References
Other rules in Frederick
Compare Frederick to another location·View the Maryland environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.