Skip to main content
CityRuleLookup

Hollywood, FL Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Governing section
Hollywood Code § 154.50(C)(1)
Residential freeboard
18 in. above street crown
Nonresidential freeboard
6 in. above street crown
Accessory structure limit
600 sq ft (100 sq ft in V-zones)
Equipment elevation
BFE plus 1 foot

Summary

New and substantially improved residential buildings in Hollywood must elevate the lowest floor at least 18 inches above the crown of the adjacent street, and nonresidential buildings at least six inches, on top of whatever the Florida Building Code's base flood elevation requires.

(C) Specific methods of construction and requirements. Pursuant to Broward County Administrative Provisions for the Florida Building Code, the following specific methods of construction and requirements apply: (1) Minimum building elevations. (a) Residential buildings. New construction and substantial improvement of residential buildings shall have the lowest floor, including basement, elevated to or above the elevation required in the Florida Building Code, Residential or Florida Building Code, Building, as applicable, or at least 18 inches above the highest point of the crown of all streets adjacent to the plot upon which such buildings are located... (b) Nonresidential buildings. New construction and substantial improvement of nonresidential buildings shall have the lowest floor, including basement, elevated or dry floodproofed to or above the elevation required in the Florida Building Code, Building or at least six inches above the highest point of the crown of all streets adjacent to the plot upon which such buildings are located...

Full Breakdown

50(C)(1) sets Hollywood's specific flood-elevation construction standard, adopted pursuant to the Broward County Administrative Provisions for the Florida Building Code. New construction and substantial improvement of residential buildings must have the lowest floor, including any basement, elevated to or above whichever is higher: the elevation the Florida Building Code requires, or at least 18 inches above the highest point of the crown of the adjacent street, unless the Director of Public Utilities approves an alternative engineering analysis. Nonresidential buildings get a smaller add-on, at least six inches above the street crown, or dry-floodproofed to that level.

21 defines BASE FLOOD ELEVATION as the elevation of the base flood, including wave height, relative to NGVD, NAVD, or the datum shown on the FIRM, the reference point the street-crown add-on sits on top of. Finished lot grading also has to sit at or above the crown of the adjacent street or top of sidewalk, whichever is higher, and the perimeter grade around a residential building must be at least six inches below the minimum building elevation. Accessory structures used only for parking or storage can sit below base flood elevation in special flood hazard areas if they are one story, no larger than 600 square feet (100 square feet in coastal high hazard V-zones), built with flood-resistant materials below base flood elevation plus one foot, and have mechanical, plumbing, and electrical systems elevated to at least one foot above base flood elevation.

Violations & Fines

A building lacking documentation of its lowest-floor elevation is presumed to be in violation under § 154.08 until the owner supplies it, and the Floodplain Administrator can issue a notice of violation or stop work order; continuing work after either is served carries the Code's general penalty under § 10.99, up to a $500 fine or 60 days imprisonment, with each day treated as a separate offense.

Frequently Asked Questions

How high above the base flood elevation must a Hollywood, FL home be built?
Section 154.50(C)(1) requires the lowest floor of a new or substantially improved residential building to sit at or above the Florida Building Code elevation, or at least 18 inches above the crown of the adjacent street, whichever is higher.
Is the freeboard requirement different for commercial buildings in Hollywood?
Yes. Nonresidential buildings only need their lowest floor elevated or dry-floodproofed to at least six inches above the street crown, versus 18 inches for residential buildings, under the same section.
Can an accessory shed sit below base flood elevation in Hollywood?
Yes, if it is used only for parking or storage, is one story, no larger than 600 square feet (100 in coastal high hazard zones), built from flood-resistant materials, and has its mechanical and electrical systems raised to at least one foot above base flood elevation, per § 154.50(D).

Sources & Official References

Other rules in Hollywood

All Hollywood rules

Florida rules heatmap·Compare Hollywood to another location·View the Florida environmental rules overview

Get notified when Flood Elevation Requirements in Hollywood, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Broward County handle flood elevation requirements.

Pembroke Pines, FL
Some Restrictions
Fort Lauderdale, FL
Some Restrictions
Pompano Beach, FL