Jacksonville Beach, FL Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Governing section
- Jacksonville Beach Code § 34-772
- Fallback base flood elevation
- Three feet above highest adjacent grade
- Zone AO design flood elevation
- Highest adjacent grade plus mapped depth number
- Zone AO default depth
- Two feet where the map prints no depth
- Elevation certificate preparer
- Florida licensed professional surveyor
- Elevated manufactured home piers
- Not less than thirty-six inches above grade
Summary
In Jacksonville Beach, section 34-772 sets the fallback when a mapped flood area has no base flood elevation: the floodplain administrator can require engineered data or specify a base flood elevation three feet above the highest adjacent grade. In Zone AO, the design flood elevation is highest adjacent grade plus the mapped depth, or two feet if none is printed.
b. Information in flood hazard areas without base flood elevations (approximate Zone A). Where flood hazard areas are delineated on the FIRM and base flood elevation data have not been provided, the floodplain administrator shall: ... ii. ... Specify that the base flood elevation is three (3) feet above the highest adjacent grade at the location of the development, provided there is no evidence indicating flood depths have been or may be greater than three (3) feet. ... Design flood elevation. ... The elevation of the "design flood," including wave height, relative to the datum specified on the community's legally designated flood hazard map. In areas designated as Zone AO, the design flood elevation shall be the elevation of the highest existing grade of the building's perimeter plus the depth number (in feet) specified on the flood hazard map. In areas designated as Zone AO where the depth number is not specified on the map, the depth number shall be taken as being equal to two (2) feet.
Official source re-checked November 3, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 60).
Full Breakdown
Where a flood hazard area is delineated on the FIRM but no base flood elevation has been provided (approximate Zone A), section 34-772(a)(5)b directs the floodplain administrator to require the applicant to include base flood elevation data prepared under currently accepted engineering practices, or to obtain and provide data available from a federal or state agency or other source. If no such data exist, the available data do not reasonably reflect flooding conditions, or the data are known to be scientifically or technically incorrect, the administrator can specify that the base flood elevation is three feet above the highest adjacent grade at the development location, provided there is no evidence that flood depths have been or may be greater than three feet. Where the data will support a letter of map change from FEMA, the analyses must be prepared by a Florida licensed engineer or professional surveyor in the format FEMA requires, and the applicant pays the processing fees.
The design flood elevation includes wave height and is measured against the datum on the community's legally designated flood hazard map. In Zone AO it equals the elevation of the highest existing grade of the building perimeter plus the depth number in feet printed on the flood hazard map. If the map prints no depth number for a Zone AO area, the depth number is taken as two feet.
For buildings and structures exempt from the Florida Building Code, the owner must submit the lowest-floor elevation proof. After the lowest floor is placed and before further vertical construction, a certification of elevation sealed by a Florida licensed professional surveyor goes to the floodplain administrator, or, where the three-foot fallback set the elevation, the owner's own documentation of the lowest floor height above the highest adjacent grade. A final certification is due at final inspection. Elevated above-ground tanks must sit at or above the design flood elevation on a supporting structure, and a manufactured home on a pier foundation must have its frame supported by piers not less than thirty-six inches above grade, or meet the Florida Building Code, Residential Section R322.2 or R322.3.
Violations & Fines
A building or structure without the documentation of the lowest floor elevation, other required design certifications, or other evidence of compliance is presumed to be a violation until that documentation is provided. For development outside the Florida Building Code, the floodplain administrator can serve notices of violation or stop work orders on the owner, the owner's agent, or the person doing the work. Continuing work after service, other than work directed to remedy the violation, brings penalties as prescribed by law.
Frequently Asked Questions
What if my lot is in a flood area with no base flood elevation?
How is design flood elevation figured in Zone AO?
Who certifies the lowest floor elevation?
Does section 34-772 print a freeboard figure for buildings?
Sources & Official References
Other rules in Jacksonville Beach
Florida rules heatmap·Compare Jacksonville Beach to another location·View the Florida environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in this county handle flood elevation requirements.