Key Facts

Residential freeboard
Lowest floor 2 feet above base flood elevation
Nonresidential option
2 ft elevation OR certified watertight floodproofing
Enclosure flood vents
1 sq in per sq ft, openings 1 ft or less above grade
Manufactured homes
Lowest floor 2 ft above BFE, anchored
RV exemption
On site under 180 days & highway-ready
Certification required
Registered engineer, architect, or surveyor

Summary

New and substantially improved homes in Leander's mapped flood hazard areas must have their lowest floor built at least two feet above the base flood elevation, a stricter freeboard than FEMA's zero-foot federal minimum. Commercial buildings can meet the same two-foot mark or be engineered watertight instead, and every design has to carry a registered engineer's, architect's, or surveyor's certification.

(1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated at least two feet above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection, as proposed in section 3.10.043(a)(1), is satisfied. ... (3)Enclosures. New construction and substantial improvements with fully enclosed areas below the lowest floor ... shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. ... (A)A minimum of two openings on separate walls having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided.(B)The bottom of all openings shall be no higher than one foot above grade.

Full Breakdown

072(1) requires that new construction and substantial improvement of any residential structure "have the lowest floor (including basement) elevated at least two feet above the base flood elevation," with a registered professional engineer, architect, or land surveyor certifying to the floodplain administrator that the standard is met. 072(2) gives nonresidential buildings, commercial, industrial or otherwise, a choice: elevate the lowest floor the same two feet, or floodproof the structure watertight with walls substantially impermeable to water and components able to resist hydrostatic and hydrodynamic loads, backed by an engineer's or architect's certified design kept on file with the floodplain administrator.

072(3) requires flood vents that automatically equalize hydrostatic pressure: a minimum of two openings on separate walls providing at least one square inch of net area per square foot of enclosed area, with the bottom of every opening no higher than one foot above grade, unless an engineer or architect certifies an equivalent design. 072(5) only if they stay on site fewer than 180 consecutive days or remain licensed, wheeled, and ready for highway use with no permanent additions; otherwise they must meet the same manufactured-home elevation and anchoring requirements. 073(c) if it isn't otherwise available, so the two-foot freeboard can be verified before lots are even platted.

Violations & Fines

Building or substantially improving a home or business below the two-foot freeboard, or finishing a below-grade enclosure without code-compliant flood vents, violates § 3.10.072 and is enforced the same way as any other floodplain violation: a Class C misdemeanor under § 3.10.013(a), with each day of continued noncompliance a separate offense. The floodplain administrator can withhold a certificate of occupancy pending a corrected elevation certificate and can revoke a permit issued on a false or misrepresented elevation.

Frequently Asked Questions

How high above the flood line does my house have to sit in Leander?
At least two feet. Section 3.10.072(1) requires new construction and substantial improvement of any residential structure to "have the lowest floor (including basement) elevated at least two feet above the base flood elevation," certified by a registered engineer, architect, or land surveyor.
Can a commercial building in the floodplain skip the elevation requirement?
Yes, if it's floodproofed instead. Section 3.10.072(2) lets nonresidential structures either elevate two feet like a home or be built watertight with walls substantially impermeable to water, backed by a certified engineered design kept on file with the floodplain administrator.
Do I need flood vents in a garage or storage area built below the flood line?
Yes. Section 3.10.072(3) requires at least two openings on separate walls with a combined net area of one square inch per square foot of enclosed area, and the bottom of each opening can't be more than one foot above grade, so floodwater can enter and exit automatically.
Are RVs exempt from Leander's flood elevation rule?
Only if they're temporary. Section 3.10.072(5) exempts a recreational vehicle that stays on site fewer than 180 consecutive days, or that's fully licensed, on its wheels, and ready for highway use. Otherwise it must meet the same two-foot elevation and anchoring standard as a manufactured home.

Sources & Official References

Other rules in Leander

All Leander rules

Texas rules heatmap·Compare Leander to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Leander, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.