Lower Paxton, PA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Elevation standard
Lowest floor at or above the regulatory flood elevation (BFE)
Nonresidential option
Floodproof enclosed space below the BFE with engineer or architect certification
Openings below lowest floor
Two openings, bottom no higher than one foot above grade
Accessory structure cap
1,000 square feet of floor area, no habitation, no sanitary facilities
Substantial improvement
50% or more of market value triggers full compliance
Penalty
Misdemeanor, $25 to $600 plus costs of prosecution
Administrator
Township Manager

Summary

In Lower Paxton Township, Dauphin County, new construction or substantial improvement in AE, A1-30 and AH flood zones must put the lowest floor, basement included, at or above the regulatory flood elevation. Chapter 108 defines that elevation as the base flood elevation. Nonresidential buildings can floodproof instead, and the Township Manager enforces the chapter as floodplain administrator.

A. Residential structures. ... (1) In AE, A1-30, and AH Zones, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation. ... (3) In AO Zones, any new construction or substantial improvement shall have the lowest floor (including basement) at or above the highest adjacent grade at least as high as the depth number specified on the FIRM. ... B. Nonresidential structures. (1) In AE, A1-30 and AH Zones, any new construction or substantial improvement of a nonresidential structure shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation, or be designed and constructed so that the space enclosed below the regulatory flood elevation: (a) Is floodproofed so that the structure is watertight with walls substantially impermeable to the passage of water; and (b) Has structural components with the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.

Full Breakdown

Section 108-23 of the Lower Paxton Township Code sets the elevation rules for every identified floodplain area. For a residential structure in an AE, A1-30 or AH Zone, the lowest floor, including a basement, must sit up to or above the regulatory flood elevation. In an A Zone where the Flood Insurance Rate Map shows no base flood elevation, the same floor rule applies, and the elevation is found under § 108-19C(2)(b): when no other information is available, the BFE is taken from a point on the boundary of the identified floodplain area nearest the construction site.

In an AO Zone the lowest floor must be at or above the highest adjacent grade at least as high as the depth number printed on the FIRM. The definitions in § 108-35 set the regulatory flood elevation equal to the base flood elevation (BFE), the water surface elevation of a flood with a 1% or greater chance of occurring in any given year. Nonresidential buildings have a second route: elevate the lowest floor, or design the enclosed space below the regulatory flood elevation to be watertight with walls substantially impermeable to water and structural components that resist hydrostatic and hydrodynamic loads and buoyancy.

Fully enclosed space below the lowest floor, crawl spaces included, needs automatic floodwater openings: at least two openings with a net total area of not less than one square inch for every square foot of enclosed space, with the bottom of every opening no higher than one foot above grade. Accessory structures need not be elevated but cannot exceed 1,000 square feet of floor area, cannot be used for habitation, and cannot contain sanitary facilities. A permit is required before any construction or development under § 108-8. Improvements costing 50% or more of a structure's market value count as a substantial improvement under § 108-31C and must meet the full chapter.

Violations & Fines

Under § 108-16B, a person who fails to comply with Chapter 108, or with a notice or order of the floodplain administrator, is guilty of a misdemeanor and pays Lower Paxton Township a fine of not less than $25 nor more than $600 plus costs of prosecution. A written notice cannot allow more than 30 days to comply. Equity actions are reserved, and the Township Manager can declare noncompliant work a public nuisance and abate it.

Frequently Asked Questions

What is the regulatory flood elevation in Lower Paxton Township?
Section 108-35 defines the regulatory flood elevation as the base flood elevation (BFE). The BFE is the water surface elevation shown on the Flood Insurance Rate Map for Zones AE, AH and A1-30 for a flood with a 1% or greater chance of being equaled or exceeded in any given year. The chapter text prints no separate added-height figure on top of the BFE.
Can a commercial building in the floodplain have space below the flood elevation?
Yes, if the space is floodproofed. Under § 108-23B, a nonresidential structure in AE, A1-30 or AH Zones can be designed so the enclosed space below the regulatory flood elevation is watertight and resists hydrostatic and hydrodynamic loads. The plans must carry a statement certified by a registered professional engineer or architect, and the work must follow the W1 or W2 classifications or an equivalent standard.
Does a garage or shed have to be raised above the flood level?
Accessory structures need not be elevated or floodproofed, but § 108-23D attaches conditions. The structure is limited to vehicle parking or storage, cannot exceed 1,000 square feet of floor area, must have low damage potential, and cannot hold sanitary facilities or permanently affixed furnaces, heaters, washers or dryers. Power lines, wiring and outlets must be elevated to the regulatory flood elevation.
Does remodeling an older house trigger the elevation rule?
Section 108-30 does not require changes to lawfully existing structures. Once an improvement is made, § 108-31 applies. Work equal to 50% or more of the structure's market value is a substantial improvement and must comply fully with Chapter 108. Expansion inside a floodway cannot cause any increase in the base flood elevation.
Who can grant relief if the elevation rule causes hardship?
Under § 108-32, the Board of Supervisors of Lower Paxton Township can grant relief from the strict application of Chapter 108 on request when compliance would cause an exceptional hardship to a prospective builder, developer or landowner. Variance procedures and conditions are in § 108-33. A boundary dispute over the mapped floodplain goes first to the Planning Commission, then the Board.

Sources & Official References

Other rules in Lower Paxton

All Lower Paxton rules

Compare Lower Paxton to another location·View the Pennsylvania environmental rules overview

Get notified when Flood Elevation Requirements in Lower Paxton, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.