Lubbock, TX Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Governing division
Article 39.05, Div. 5.1, Flood Damage Prevention
Minimum freeboard test
1 ft above FIRM or Master Drainage Plan elevation
Playa lake freeboard
2 ft above playa lake overflow elevation
Street-based freeboard
18 in above adjacent street gutter elevation
Administering official
City Engineer as Floodplain Administrator
Violation
Misdemeanor, separate offense per day (§ 39.05.008)

Summary

Lubbock's floodplain code requires new and substantially improved homes in special flood hazard areas to raise their lowest floor above the base flood elevation using the most restrictive of six freeboard tests set by the City Engineer as Floodplain Administrator.

New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities, including ductwork, elevated to the most restrictive flood protection elevation as set forth below. 1. Lowest floor elevation. A. One foot above the one percent annual chance flood elevation established by the City of Lubbock Master Drainage Plan; B. If located in a flood hazard area, the lowest floor (including basement) will be one foot above the flood elevation established by the FIRM of the Federal Emergency Management Agency (FEMA); C. Two feet above the applicable playa lake overflow elevation; D. Eighteen inches above the highest gutter elevation (or if no curb and gutter is present, one foot above top of crown) of the nearest adjacent street(s); E. Six inches above the calculated peak water surface elevation if a design waiver is granted in accordance with the Drainage Criteria Manual; or F. One foot above the 500-year 24-hour base flood elevation if located within the limits of a non-overflow playa lake.

Full Breakdown

013, Specific standards. For residential construction, the lowest floor, including the basement and all electrical, heating, ventilation, plumbing and air conditioning equipment and ductwork, must be raised to whichever freeboard requirement is most restrictive: one foot above the one percent annual chance flood elevation from the City's Master Drainage Plan; one foot above the FEMA Flood Insurance Rate Map (FIRM) elevation; two feet above the applicable playa lake overflow elevation; eighteen inches above the highest adjacent street gutter (or one foot above the crown where there is no curb and gutter); six inches above the calculated peak water surface elevation if a design waiver is granted under the Drainage Criteria Manual; or one foot above the 500-year 24-hour base flood elevation for sites within a non-overflow playa lake.

013(c), or may instead be floodproofed watertight below the base flood level, with a floodproofing certificate kept on file by the Floodplain Administrator. 013(b)(2). 013(d). 013(e)-(f). 009.

Violations & Fines

Constructing, locating, extending, converting, or altering any structure or land without complying with Division 5.1 is a misdemeanor under § 39.05.008, enforced through Article 39.09, Enforcement and Remedies. Each day a violation continues counts as a separate offense, so unpermitted or under-elevated construction in a floodplain can accrue daily penalties, and the City may pursue other lawful remedies beyond criminal prosecution to force compliance or removal.

Frequently Asked Questions

How high above flood level must a new Lubbock home be built?
The lowest floor, including the basement and all mechanical equipment, must meet the most restrictive of several tests under § 39.05.013, commonly one foot above the FEMA FIRM elevation, two feet above playa lake overflow, or eighteen inches above the adjacent street gutter, whichever is highest.
Who certifies that a Lubbock building meets the flood elevation rule?
A registered professional engineer, architect, or land surveyor must submit a certificate to the City Engineer, acting as Floodplain Administrator, confirming the elevation standard in § 39.05.013(b) has been met before the project can proceed.
What happens if a structure is built below the required flood elevation in Lubbock?
Section 39.05.008 makes noncompliant construction a misdemeanor, with each day the violation continues treated as a separate offense, and the City can also take other lawful action under Article 39.09 to require correction.

Sources & Official References

Other rules in Lubbock

All Lubbock rules

Texas rules heatmap·Compare Lubbock to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Lubbock, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.