Key Facts
- Residential lowest floor
- No lower than one foot above base flood elevation
- Also elevated
- Basement, mechanical equipment and ductwork
- AO zone without a depth number
- At least two feet above highest adjacent grade
- Final check
- Engineer or surveyor certifies, building inspection verifies
- Enclosure openings
- One square inch of net area per square foot enclosed
- Penalty
- Fine of no less than $250 or up to 90 days
Summary
In Murray, new residential construction and substantial improvements in a special flood hazard area with base flood elevation data must have the lowest floor, basement, mechanical equipment and ductwork elevated no lower than one foot above the base flood elevation, under Murray Code of Ordinances § 152.41(A). An engineer or surveyor certifies the finished elevation.
In all special flood hazard areas where base flood elevation data have been provided, as set forth in § 152.08, the following provisions are required: (A) Residential construction . (1) New construction or substantial improvement of any residential structure (or manufactured home) shall have the lowest floor, including basement, mechanical equipment, and ductwork elevated no lower than one foot above the base flood elevation. ... (a) In an AO zone, elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. ... (c) In all other zones, elevated one foot above the base flood elevation. (2) Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community building inspection department to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator.
Full Breakdown
Section 152.41 applies in all special flood hazard areas where base flood elevation data have been provided. For new construction or substantial improvement of a residential structure or manufactured home, the lowest floor, including basement, mechanical equipment and ductwork, must be elevated no lower than one foot above the base flood elevation. That extra foot is the freeboard: Chapter 152 defines freeboard in § 152.04 as a factor of safety applied above the base flood elevation, and says it must reach the level of protection for building utilities and HVAC components, not only the lowest floor.
The residential rule has zone-specific versions. In an AO zone the structure is elevated above the highest adjacent grade to a height equal to or exceeding the depth number in feet on the FIRM, or at least two feet above the highest adjacent grade if no depth number is specified. In an A zone with no FEMA technical data, the structure is elevated one foot above the base flood elevation as determined by the community, and the Floodplain Administrator decides the method. In all other zones it is one foot above the base flood elevation. When the work is finished, a registered professional engineer or surveyor certifies the lowest floor elevation and the community building inspection department verifies it, with both documents going to the Floodplain Administrator.
Non-residential buildings must either meet the residential elevation rule or be floodproofed below an elevation one foot above the base flood elevation so the structure is watertight, with a registered professional engineer or architect certifying it. Fully enclosed areas below the lowest floor that are usable only for parking, building access or storage must use flood resistant materials and have openings with a total net area of not less than one square inch for every square foot of enclosed area, with the bottom of each opening no higher than one foot above grade. Elevated structures on columns, posts or pilings must be designed to preclude finished living space below the base flood elevation.
Violations & Fines
Building below the required elevation is a violation of Chapter 152 and a misdemeanor criminal offense under §§ 152.07 and 152.99. A fine of no less than $250 or imprisonment of not more than 90 days, or both, plus costs, follows conviction, and each day is a separate offense. The Floodplain Administrator can issue a notice requiring a remedy within a reasonable time, which can include a stop-work order under § 152.57.
Frequently Asked Questions
How high must a new house in a Murray flood zone be built?
What is freeboard in Murray's flood ordinance?
Who checks the finished elevation?
Can a commercial building be floodproofed instead of raised?
Sources & Official References
Other rules in Murray
Compare Murray to another location·View the Kentucky environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.