Skip to main content
CityRuleLookup

Tangipahoa Parish, LA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
12 inches above base flood elevation
Applies to
new construction and substantial improvements
Certification by
registered engineer, architect or land surveyor
Small appurtenant structures
under 550 sq ft need flood-equalizing openings, not elevation
FIRM basis
FEMA Flood Insurance Study dated July 22, 2010
Max penalty
$500.00 fine or 30 days jail per violation

Summary

New and substantially improved residential structures in Tangipahoa Parish flood hazard areas must have their lowest floor, including any basement, elevated at least 12 inches above the base flood elevation. An engineer, architect or land surveyor must certify compliance to the parish floodplain administrator before the permit is finalized.

These county ordinances apply to unincorporated areas of Tangipahoa Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Sec. 36-285. - Specific standards. In all areas of special flood hazard where base flood elevation data has been provided as set forth in section 36-243, 36-266(a)(8), or 36-286(c), the following provisions are required: ... (1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated to at least 12 inches above the base flood elevation.a.A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection, as proposed in section 36-266(a), is satisfied.

Full Breakdown

Parish Code section 36-285 sets the specific flood-hazard-reduction standards that apply once base flood elevation data has been established for a site under sections 36-243, 36-266(a)(8) or 36-286(c). For residential construction, the lowest floor, including a basement, must sit at least 12 inches above the base flood elevation (BFE), and a registered professional engineer, architect or land surveyor must certify that standard to the floodplain administrator. Nonresidential structures may instead be floodproofed watertight below the BFE if an engineer certifies the design. Standalone enclosed appurtenant structures under 550 square feet need hydrostatic flood-equalizing openings rather than full elevation, while those 550 square feet or larger must be elevated to the BFE plus the required freeboard like a primary structure.

In coastal high hazard zones (V, VE, V1-30), section 36-289 pushes the same 12-inch freeboard requirement onto pilings and columns, measured to the bottom of the lowest horizontal structural member, reflecting the added risk from hurricane wave action and tidal surge. Base flood elevation itself comes from the FEMA Flood Insurance Study and accompanying Flood Insurance Rate Maps for Tangipahoa Parish, dated July 22, 2010, and any later revisions, adopted by reference under section 36-243. The floodplain administrator, appointed by the parish president, reviews elevation certificates and can require additional engineering data when FIRM data is incomplete for a parcel. 00 in fines or 30 days in jail per violation, with each day of noncompliance counted separately, and violators also cover court costs.

Violations & Fines

Failing to elevate the lowest floor at least 12 inches above base flood elevation, or building without the required engineer or surveyor certification, is enforced as a violation of Article IX under section 36-249: a misdemeanor carrying a fine up to $500.00, up to 30 days imprisonment, or both, with each day of continuing noncompliance treated as a new offense.

Frequently Asked Questions

How high above base flood elevation must a house be built in Tangipahoa Parish?
Section 36-285(1) requires the lowest floor, including any basement, to sit at least 12 inches above the base flood elevation shown on the parish's FEMA Flood Insurance Rate Map. A registered engineer, architect or land surveyor must certify the elevation to the floodplain administrator.
Does the freeboard rule apply to sheds and detached garages?
Only if they are 550 square feet or larger; those must be elevated to the base flood elevation plus freeboard like a house. Smaller standalone appurtenant structures instead need hydrostatic flood-equalizing openings under section 36-285(1)b.
What is base flood elevation based on in Tangipahoa Parish?
Section 36-243 adopts by reference the FEMA Flood Insurance Study for Tangipahoa Parish and its accompanying Flood Insurance Rate Maps, both dated July 22, 2010, plus any later FEMA revisions, as the source of special flood hazard area boundaries and elevations.

Sources & Official References

Other rules in Tangipahoa Parish

All Tangipahoa Parish rules

Compare Tangipahoa Parish to another location·View the Louisiana environmental rules overview

Get notified when Flood Elevation Requirements in Tangipahoa Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.