Skip to main content
CityRuleLookup

New York, NY Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Required freeboard
2 feet above base flood elevation
Applies to
new builds & substantial improvements in SFHAs
Enforced by
DOB commissioner, city floodplain administrator
Coastal high-hazard areas
same 2-ft freeboard under Table 4-1
Governing standard
ASCE 24-14, as amended by NYC

Summary

New York City's Building Code requires new construction and substantially improved buildings in FEMA flood hazard areas to elevate the lowest floor at least 2 feet above the base flood elevation, a citywide freeboard margin set by amendments to ASCE 24-14.

Table 2-1 of Section 2.3 (Elevation Requirements) is amended to read as follows: Table 2-1 Minimum Elevation of the Top of Lowest Floor. Flood Design Class 1: DFE = BFE + 2 ft. Flood Design Class 2: DFE = BFE + 2 ft. Flood Design Class 3: DFE = BFE + 2 ft. Flood Design Class 4: DFE = BFE + 2 ft, or 500-year flood elevation, whichever is higher.

Full Breakdown

NYC Building Code Appendix G designates the DOB commissioner as floodplain administrator for FEMA-mapped Special Flood Hazard Areas. Under the city's amendments to ASCE 24-14 (Table 2-1 and Table 4-1), new construction and substantial improvements, including in coastal high-hazard V-Zones and Coastal A-Zones, must have their lowest floor, or lowest horizontal structural member in coastal zones, at least 2 feet above the base flood elevation (BFE), yielding a design flood elevation (DFE) of BFE+2 ft for every Flood Design Class. Applicants must first submit sealed flood zone compliance plans showing the base and design flood elevations before DOB will issue a permit.

Violations & Fines

DOB will not approve permits or issue a certificate of occupancy without flood zone compliance plans meeting Appendix G; noncompliant construction risks stop-work orders and civil penalties under Title 28's violations provisions (Admin Code Ch. 2).

Frequently Asked Questions

How much freeboard does NYC require above the base flood elevation?
NYC Building Code Appendix G requires new buildings and substantial improvements in FEMA Special Flood Hazard Areas to elevate the lowest floor at least 2 feet above the base flood elevation, per the city's amended ASCE 24-14 Table 2-1.
Does the 2-foot freeboard rule apply in coastal V-Zones too?
Yes. Table 4-1 sets the same DFE = BFE + 2 ft standard for the lowest horizontal structural member of buildings in coastal high-hazard areas and Coastal A-Zones.

Sources & Official References

Other rules in New York

All New York rules

New York rules heatmap·Compare New York to another location·View the New York environmental rules overview

Get notified when Flood Elevation Requirements in New York, NY changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.