Key Facts

Freeboard
1 foot above Base Flood Elevation (A/AE)
AO/AH zones
Depth number + 1 ft above grade, 3 ft min
Applies to
New construction and substantial improvement
Recordkeeping
Elevation Certificate required
Nonresidential option
Floodproof instead of elevate
Reference standard
ASCE/SEI 24-14 Table 2-1; N.J.A.C. 7:13-3

Summary

New residential construction and substantial improvements in Newark's A, AE, AO or AH flood zones must have the lowest floor, including any basement, elevated at least one foot above the base flood elevation shown on FEMA's Flood Insurance Rate Map, under Section 12:4-6.1 of the City Code. Nonresidential buildings can meet the same freeboard by elevating, or instead by floodproofing, under Section 12:4-6.2.

New construction and substantial improvement of any residential structure located in an A, AE, AO or AH zone shall have the lowest floor, including basement together with the attendant utilities (including all electrical, heating, ventilating, air-conditioning and other service equipment) and sanitary facilities, elevated at or above the more restrictive of the following: ... For A or AE zones: (a) Base flood elevation (published FIS/FIRM) plus one foot; (b) The best available flood hazard data elevation plus one foot; (c) As required by ASCE/SEI 24-14, Table 2-1; or (d) As required by N.J.A.C. 7:13-3.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 5019615; v61 updated 2026-06-17; through 06-17-2026).

Full Breakdown

1, added when Newark rewrote Title XII in its entirety on March 24, 2020, by Ordinance No. 6PSF-A, sets the elevation standard for residential structures in mapped special flood hazard areas. C. 7:13-3. In AO or AH zones, the structure must clear the depth number shown on the municipality's FIRM plus one foot above the highest adjacent grade, with a three foot minimum if no depth number is mapped, and the design must route drainage around the structure on sloped sites. Builders record the elevation method and data source used in the local Development Permit.

2 applies a parallel standard to commercial, industrial and other nonresidential structures, but lets an owner choose floodproofing instead of elevation: the space below the freeboard-adjusted base flood elevation must be watertight, substantially impermeable to water, and able to resist hydrostatic and hydrodynamic loads and buoyancy, certified by a registered professional engineer or architect. Section 12:4-5 separately requires any enclosed area below the lowest floor used only for parking, access or storage to have flood vents totaling at least one square inch of net opening per square foot of enclosed area, with the lowest opening no higher than one foot above grade, so floodwaters can enter and exit without damaging the structure.

Violations & Fines

Building or substantially improving a structure below the required freeboard elevation violates Title XII and is enforced the same way as any other flood-title violation: Section 12:2-4 makes it a misdemeanor punishable by a fine of up to $300 for each day the violation continues, imprisonment up to 90 days, or both, plus case costs. A structure built too low also cannot receive the Elevation Certificate the Flood Control Compliance Officer must record under Section 12:3-5, which can block a certificate of occupancy and raise flood insurance costs.

Frequently Asked Questions

How much freeboard does Newark require above base flood elevation?
At least one foot. Section 12:4-6.1 requires new or substantially improved residential structures in A or AE zones to elevate the lowest floor, including the basement, to the published base flood elevation plus one foot, or higher if ASCE/SEI 24-14 or N.J.A.C. 7:13-3 demands more.
Does the freeboard rule apply to home additions?
Yes. Section 12:4-6.1 covers both new construction and substantial improvement of existing residential structures in mapped flood zones, so an addition or renovation that counts as a substantial improvement must meet the same one-foot freeboard above base flood elevation required of a brand-new house.
What if my Newark property is in an AO or AH zone instead of AE?
Section 12:4-6.1 requires elevating above the depth number shown on the municipality's Flood Insurance Rate Map plus one foot above the highest adjacent grade, with a minimum of three feet of clearance if the map does not list a specific depth number for that AO or AH zone.
Can a commercial building in Newark floodproof instead of elevating?
Yes. Section 12:4-6.2 lets nonresidential structures in A or AE zones choose floodproofing instead of physical elevation, provided the space below the freeboard-adjusted base flood elevation is watertight and can resist hydrostatic and hydrodynamic forces, with the design certified by a registered professional engineer or architect.

Sources & Official References

Other rules in Newark

All Newark rules

Compare Newark to another location·View the New Jersey environmental rules overview

Get notified when Flood Elevation Requirements in Newark, NJ changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.