Key Facts

Residential lowest floor
Base flood elevation plus 24 inches, basement included
Mechanical equipment
Elevated or floodproofed to 2 feet above base flood elevation
AO zone floor
2 feet above mapped depth, or 4 feet above grade if none
Required certificate
FEMA elevation certificate with the zoning permit application
Flood openings
Two openings, 1 square inch per square foot of enclosure
Substantial improvement
Cost of 50 percent of market value over 5 years
Enforcing office
Zoning Administrator, Department of Planning, Building, and Development

Summary

Roanoke requires new homes and substantial improvements in the Floodplain Overlay District (F) to put the lowest floor, basement included, at the base flood elevation plus 24 inches of freeboard. Furnace, plumbing, electrical and air conditioning equipment must sit or be floodproofed at 2 feet above the base flood elevation.

The City requires base flood elevation plus twenty-four (24) inches freeboard. ... Lowest floor: The lowest floor of the lowest enclosed area (including basement). ... Residential Construction. New construction or substantial improvement of any residential structure in Zones A1-30, AE, AH and A with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood level plus twenty-four (24) inches of freeboard. In addition, all electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities, including ductwork, for new construction or substantial improvement shall be elevated or floodproofed to two (2) feet above the base flood elevation, also known as two (2) feet of freeboard.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 94 Update 1).

Full Breakdown

The rule sits in Roanoke City Code Sec. 36.2-333, the Floodplain Overlay District (F), which applies to every special flood hazard area on the FEMA flood insurance rate map. Under subsection (e)(3)(A), a new residential building or a substantial improvement in Zones A1-30, AE, AH and A with detailed base flood elevations must have its lowest floor elevated to or above the base flood level plus 24 inches. The definition of lowest floor counts a basement, so a basement slab cannot sit below that line. Mechanical systems follow a separate 2-foot rule: electrical, heating, ventilation, plumbing and air conditioning equipment, including ductwork, must be elevated or floodproofed to 2 feet above the base flood elevation.

Subsection (e)(3)(B) applies the same 24 inches to commercial, industrial and other non-residential buildings, with one alternative. In AE, AH and A1-30 zones a non-residential building can be dry floodproofed instead of elevated, but only if everything below the freeboard line is watertight, and a registered professional engineer or architect must certify it. Detached garages, small pole barns, storage sheds, gazebos and picnic shelters can be wet floodproofed.

AO zones, which are shallow flooding areas, work differently. The lowest floor must be 2 feet above the flood depth printed on the map, measured from the highest adjacent grade. Where the map prints no depth, the floor must be at least 4 feet above the highest adjacent grade. In unnumbered A Zones, the applicant must determine the base flood elevation from federal or state data or an engineer's analysis, and the same 24 inches applies.

Paperwork drives the process. Every zoning permit application for a structure needs a FEMA elevation certificate from a licensed surveyor or engineer, and a final as-built elevation certificate is due before a Certificate of Occupancy issues. Enclosed space below the required elevation cannot be habitable and is limited to parking, building access and limited storage. It needs at least two openings on different sides, with 1 square inch of net opening for each square foot of enclosed area, and the bottom of each opening no more than 1 foot above grade. Existing buildings must comply when a repair or improvement costs 50 percent or more of market value over 5 years.

Violations & Fines

The Zoning Administrator enforces the floodplain rules and starts with a written notice that names the violation and orders the fix. A violation of Chapter 36.2 is a misdemeanor punishable under Section 15.2-2286.A.5 of the Code of Virginia, and the City can also seek an injunction. Each day a violation continues after notification counts as a separate offense. A structure built without the required elevation certificate is presumed to be in violation until the certificate is provided. A permit obtained with materially misleading information can be revoked, and the revocation can be appealed to the Board of Zoning Appeals.

Frequently Asked Questions

How high must the lowest floor be in a Roanoke flood zone?
For new residential construction and substantial improvements in Zones A1-30, AE, AH and A with detailed base flood elevations, the lowest floor must be at or above the base flood level plus 24 inches. The City code defines the lowest floor to include a basement, so basements must be raised or filled to the same height as the main floor.
Does the 24 inch freeboard apply to commercial buildings?
Yes. Subsection (e)(3)(B) puts commercial, industrial and other non-residential buildings at the same base flood level plus 24 inches. The difference is that a non-residential building in an AE, AH or A1-30 zone can be dry floodproofed instead, with watertight walls below that line and a certification from a registered professional engineer or architect.
What paperwork does Roanoke require before and after construction?
Every zoning permit application for a structure must include a standard FEMA elevation certificate completed by a licensed surveyor or engineer. Non-residential buildings being floodproofed also need a FEMA floodproofing certificate when applicable. Before a Certificate of Occupancy is issued, the applicant must supply a final elevation certificate showing the as-built elevation.
Can I finish a basement or enclosed area below the flood elevation?
No, not for living space. Fully enclosed areas below the regulatory flood protection elevation cannot be designed or used for human habitation and are limited to parking, building access and limited storage. They must use flood resistant materials and have at least two openings on different sides totaling 1 square inch per square foot of enclosed area.
Can the Board of Zoning Appeals grant a variance from the elevation rule?
Only for good and sufficient cause and after the Board finds that denial would cause exceptional hardship. The Board must send the applicant written notice that building below the base flood elevation raises risk to life and property and increases flood insurance premiums. No variance is allowed in a floodway if it raises the flood elevation.

Sources & Official References

Other rules in Roanoke

All Roanoke rules

Compare Roanoke to another location·View the Virginia environmental rules overview

Get notified when Flood Elevation Requirements in Roanoke, VA changes