Skip to main content
CityRuleLookup

Roanoke, VA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard requirement
Base flood elevation plus 24 inches
Mechanical equipment standard
2 feet above base flood elevation
Governing section
City Code Sec. 36.2-333(b), (e)(3)
Administering official
Zoning Administrator

Summary

Roanoke requires new and substantially improved buildings in special flood hazard areas to elevate the lowest floor to the base flood elevation plus 24 inches of freeboard, with mechanical equipment raised or floodproofed to the same standard.

Freeboard: A factor of safety usually expressed in feet above a flood level for purposes of floodplain management. "Freeboard" tends to compensate for the many unknown factors that could contribute to flood heights greater than the height calculated for a selected size flood and floodway conditions, such as wave action, bridge openings, and the hydrological effect of urbanization in the watershed. The City requires base flood elevation plus twenty-four (24) inches freeboard. ... (e)(3)(A) Residential Construction. New construction or substantial improvement of any residential structure in Zones A1-30, AE, AH and A with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood level plus twenty-four (24) inches of freeboard.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 94 Update 1).

Full Breakdown

City Code Sec. 2-333(b) defines freeboard as the safety margin above the base flood elevation that compensates for unknown factors like wave action and urbanization runoff, and states flatly that the City requires base flood elevation plus twenty-four inches of freeboard. That standard is operationalized in Sec. 2-333(e)(3)(A): new construction or substantial improvement of a residential structure in Zones A1-30, AE, AH, or A with detailed base flood elevations must have its lowest floor, including any basement, elevated to or above the base flood level plus twenty-four inches.

Electrical, heating, ventilation, plumbing, air conditioning equipment, and ductwork must independently be elevated or floodproofed to two feet above the base flood elevation. The same 24-inch freeboard floor applies to commercial, industrial, and other non-residential buildings under Sec. 2-333(e)(3)(B), though non-residential structures may substitute floodproofing for elevation if a registered engineer or architect certifies the building is watertight to that height. The Zoning Administrator administers these standards, reviewing site plans and FEMA elevation certificates before permitting and again before issuing a certificate of occupancy. Applicants in areas with base flood elevation data but no FEMA-established datum still must elevate to that level plus 24 inches once the Zoning Administrator determines the base flood elevation using accepted engineering methods under Sec. 2-333(d)(2)(C)(i).

Violations & Fines

Building below the required freeboard elevation without an approved floodproofing certification is a violation of the City's floodplain management regulations, and Sec. 36.2-333(a)(7) directs enforcement and penalties to Section 36.2-571 of the City Code. A structure lacking a FEMA elevation certificate or other compliance documentation is presumed in violation until documentation is produced, and the Zoning Administrator can issue stop-work orders and require corrective action.

Frequently Asked Questions

How high above the flood line must a new house be built in Roanoke?
The lowest floor, including any basement, must sit at or above the base flood elevation plus 24 inches of freeboard under Sec. 36.2-333(e)(3)(A), and HVAC and plumbing equipment must be elevated or floodproofed to 2 feet above base flood elevation.
Can a commercial building in Roanoke's floodplain be floodproofed instead of elevated?
Yes, under Sec. 36.2-333(e)(3)(B)(ii) non-residential buildings in A1-30, AE, and AH zones may be floodproofed to the base flood elevation plus 24 inches instead of elevated, provided a registered engineer or architect certifies the structure is watertight.
What document does Roanoke require to prove a building meets the freeboard rule?
Applicants must submit a FEMA elevation certificate completed by a licensed surveyor or engineer with the zoning permit application, and a final as-built elevation certificate before the Zoning Administrator will issue a certificate of occupancy.

Sources & Official References

Other rules in Roanoke

All Roanoke rules

Compare Roanoke to another location·View the Virginia environmental rules overview

Get notified when Flood Elevation Requirements in Roanoke, VA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.