Saint Paul, MN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard requirement
- At least 2 feet above regional flood
- Applies to
- Lowest floor, including basement
- Fill elevation limit
- No lower than 1 foot below RFPE
- Fill extension
- At least 15 feet beyond structure
- Small accessory exception
- 500 sq ft or less, internally floodproofed
- Vehicular access standard
- Within 2 feet of RFPE
Summary
Saint Paul defines the 'regulatory flood protection elevation' as at least 2 feet above the regional (100-year) flood's water surface profile, per Sec. 68.114. In the FF Flood Fringe District, Sec. 68.172(a) requires new structures' lowest floor, including any basement, to sit at or above that elevation, with fill extending at least 15 feet beyond the structure.
Regulatory flood protection elevation. That elevation not less than two (2) feet above the water surface profile associated with the regional flood plus any increase in flood heights attributable to encroachments on the floodplain. ... (a)All structures with a roof and a wall or attachment to utilities, including gas and liquid storage tanks and accessory structures, must be elevated on fill so that the lowest floor including basement floor is at or above the regulatory flood protection elevation. The finished fill elevation for such structures shall be not lower than one (1) foot below the regulatory flood protection elevation and the fill shall extend at such elevation at least fifteen (15) feet beyond the outside limits of the structure erected thereon.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 133 Update 1).
Full Breakdown
Sec. 114 defines 'regulatory flood protection elevation' as the elevation not less than 2 feet above the water surface profile of the regional flood, the flood with a 1 percent annual chance, synonymous with the FEMA 'base flood', plus any increase in flood heights from encroachments on the floodplain. That 2-foot freeboard becomes the operative construction standard under Sec. 172(a): every structure with a roof and a wall, plus attached utilities, gas and liquid storage tanks, and accessory structures in the FF Flood Fringe District must be elevated on fill so the lowest floor, including any basement, sits at or above the regulatory flood protection elevation, and the finished fill can be no lower than 1 foot below that elevation while extending at least 15 feet beyond the structure's outside limits.
Sec. 172(b) allows a fallback for small accessory structures, 500 square feet or less at ground level, to be internally floodproofed instead of elevated on fill under Sec. 164(e). Structures that skip elevation or floodproofing under Sec. 172 need a conditional use permit under Sec. 173, and Sec. 174 sets out alternatives such as stilts, piers, or above-grade crawl spaces designed to flood internally, plus limits on residential basement construction below the regulatory flood protection elevation. Sec. 175(a) also requires new principal structures to have vehicular access at an elevation no more than 2 feet below the regulatory flood protection elevation.
All of these standards trace to Ord. No. 25-72, adopted December 10, 2025, and implement Minn. ch. 103F and the National Flood Insurance Program's 44 CFR Parts 59-78.
Violations & Fines
Placing a structure's lowest floor below the regulatory flood protection elevation without a conditional use permit or approved floodproofing violates Sec. 68.172 and 68.173, and under Sec. 68.124 anyone who does get a variance or conditional use permit to build below that elevation must be notified their flood insurance premium could rise as high as $25 per $100 of coverage. The zoning administrator keeps a permanent record of every structure's lowest-floor elevation under Sec. 68.121(f).
Frequently Asked Questions
What is the 'regulatory flood protection elevation' in Saint Paul?
How high does my house's lowest floor need to sit in the flood fringe district?
Is there any way around elevating a structure on fill?
Sources & Official References
Other rules in Saint Paul
Compare Saint Paul to another location·View the Minnesota environmental rules overview