Skip to main content
CityRuleLookup

Scranton, PA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
1.5 feet above base flood elevation
Applies to
AE, A1-30, AH flood zones
Covers
Lowest floor, including basement
AO zones
Highest adjacent grade plus FIRM depth
Manufactured homes
Same 1.5-foot elevation minimum
Certification to
Building Code Official, Zoning Officer

Summary

Scranton's Zoning Code requires new construction and substantial improvements in the AE, A1-30 and AH flood zones to elevate the lowest floor, including any basement, up to or above the regulatory flood elevation under § 445-14C(2)(a). That elevation, defined in § 445-14L(2), is the base flood elevation plus a required one-and-a-half-foot freeboard safety margin.

Residential structures. In AE, A1-30, and AH Zones, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation. [...] REGULATORY FLOOD ELEVATION: The base flood elevation (BFE) or estimated flood height as determined using simplified methods plus a freeboard safety factor of 1 1/2 feet.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4719898; v25 updated 2025-12-16; through 12-16-2025).

Full Breakdown

The Floodplain Overlay in § 445-14 of Chapter 445, Zoning, defines a base flood as the flood with a one-percent chance of occurring in any given year, and defines regulatory flood elevation in § 445-14L(2) as the base flood elevation, or an estimated flood height determined by simplified methods, plus a freeboard safety factor of one and one-half feet. Section 445-14C(2)(a) requires new construction or substantial improvement of a residential structure in an AE, A1-30, or AH zone to have its lowest floor, including any basement, elevated up to or above that regulatory flood elevation; in AO zones without base flood elevations, the standard instead is the highest adjacent grade plus the depth number shown on the Flood Insurance Rate Map.

Nonresidential structures may elevate to the same standard or, in the alternative, be floodproofed below the regulatory flood elevation to the W1 or W2 watertight standards in the Army Corps of Engineers' 'Flood-Proofing Regulations' publication, certified by a registered engineer or architect. 5-foot minimum. New streets built within the floodplain cannot have a finished elevation more than one foot below the regulatory flood elevation, and permit applicants must submit lowest-floor elevation certifications to the Building Code Official and Zoning Officer.

Violations & Fines

Building or substantially improving a structure in an AE, A1-30, or AH flood zone without elevating the lowest floor, including any basement, to or above the regulatory flood elevation violates § 445-14C(2), and the applicant must submit floor-elevation certifications to the Building Code Official and Zoning Officer before a permit issues. Streets built in the floodplain more than one foot below the regulatory flood elevation, and equipment or storage placed below that elevation instead of at or above it, also violate the section's construction standards.

Frequently Asked Questions

How high above flood level must a new Scranton home be built?
Section 445-14C(2)(a) requires new construction or substantial improvement of a residential structure in an AE, A1-30, or AH flood zone to have its lowest floor, including any basement, elevated up to or above the regulatory flood elevation. Section 445-14L(2) defines that elevation as the base flood elevation plus a one-and-a-half-foot freeboard safety margin.
What is freeboard in Scranton's flood rules?
Freeboard is the extra safety margin the City adds on top of the FEMA base flood elevation before treating a floor as compliant. Section 445-14L(2) sets that margin at one and one-half feet, so the regulatory flood elevation used for permitting is always the base flood elevation plus 1.5 feet.
Can a commercial building in a Scranton flood zone skip elevating and floodproof instead?
Yes, for nonresidential structures. Section 445-14C(2) lets a nonresidential building in an AE, A1-30, or AH zone either elevate its lowest floor to the regulatory flood elevation or be floodproofed below that elevation to the W1 or W2 watertight standards published by the U.S. Army Corps of Engineers, certified by a registered engineer or architect.
Do manufactured homes get the same freeboard requirement?
Yes. The floodplain overlay requires a manufactured home to be elevated so its lowest floor sits at least one and one-half feet above the base flood elevation, matching the freeboard margin used for the regulatory flood elevation applied to other new construction and substantial improvements in the mapped flood zones.

Sources & Official References

Other rules in Scranton

All Scranton rules

Compare Scranton to another location·View the Pennsylvania environmental rules overview

Get notified when Flood Elevation Requirements in Scranton, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.