Scranton, PA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard required
- 1.5 feet above base flood elevation
- Applies to
- AE, A1-30, AH flood zones
- Covers
- Lowest floor, including basement
- AO zones
- Highest adjacent grade plus FIRM depth
- Manufactured homes
- Same 1.5-foot elevation minimum
- Certification to
- Building Code Official, Zoning Officer
Summary
Scranton's Zoning Code requires new construction and substantial improvements in the AE, A1-30 and AH flood zones to elevate the lowest floor, including any basement, up to or above the regulatory flood elevation under § 445-14C(2)(a). That elevation, defined in § 445-14L(2), is the base flood elevation plus a required one-and-a-half-foot freeboard safety margin.
Residential structures. In AE, A1-30, and AH Zones, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation. [...] REGULATORY FLOOD ELEVATION: The base flood elevation (BFE) or estimated flood height as determined using simplified methods plus a freeboard safety factor of 1 1/2 feet.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4719898; v25 updated 2025-12-16; through 12-16-2025).
Full Breakdown
The Floodplain Overlay in § 445-14 of Chapter 445, Zoning, defines a base flood as the flood with a one-percent chance of occurring in any given year, and defines regulatory flood elevation in § 445-14L(2) as the base flood elevation, or an estimated flood height determined by simplified methods, plus a freeboard safety factor of one and one-half feet. Section 445-14C(2)(a) requires new construction or substantial improvement of a residential structure in an AE, A1-30, or AH zone to have its lowest floor, including any basement, elevated up to or above that regulatory flood elevation; in AO zones without base flood elevations, the standard instead is the highest adjacent grade plus the depth number shown on the Flood Insurance Rate Map.
Nonresidential structures may elevate to the same standard or, in the alternative, be floodproofed below the regulatory flood elevation to the W1 or W2 watertight standards in the Army Corps of Engineers' 'Flood-Proofing Regulations' publication, certified by a registered engineer or architect. 5-foot minimum. New streets built within the floodplain cannot have a finished elevation more than one foot below the regulatory flood elevation, and permit applicants must submit lowest-floor elevation certifications to the Building Code Official and Zoning Officer.
Violations & Fines
Building or substantially improving a structure in an AE, A1-30, or AH flood zone without elevating the lowest floor, including any basement, to or above the regulatory flood elevation violates § 445-14C(2), and the applicant must submit floor-elevation certifications to the Building Code Official and Zoning Officer before a permit issues. Streets built in the floodplain more than one foot below the regulatory flood elevation, and equipment or storage placed below that elevation instead of at or above it, also violate the section's construction standards.
Frequently Asked Questions
How high above flood level must a new Scranton home be built?
What is freeboard in Scranton's flood rules?
Can a commercial building in a Scranton flood zone skip elevating and floodproof instead?
Do manufactured homes get the same freeboard requirement?
Sources & Official References
Other rules in Scranton
Compare Scranton to another location·View the Pennsylvania environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.