Key Facts
- Residential, riverine zones
- Lowest floor, including basement, one foot above BFE
- Coastal V and VE zones
- Lowest structural member bottom one foot above base flood level
- Non-residential, riverine
- At or above BFE, or floodproofed with engineer certification
- Manufactured dwellings
- Chassis frame beam bottom at or above BFE
- Flood openings
- Two openings, one square inch per square foot enclosed
- Substantial improvement
- Cost equals or exceeds 50 percent of market value
- Penalty
- Misdemeanor: fine up to $500.00, up to 180 days, or both
Summary
In Seaside riverine flood zones, new residential construction and substantial improvements must have the lowest floor, including basement, elevated a minimum of one foot above the Base Flood Elevation. In coastal V and VE zones the bottom of the lowest horizontal structural member must sit a minimum of one foot above the base flood level. Riverine non-residential buildings can instead be floodproofed.
152.5.2.3.2 RESIDENTIAL CONSTRUCTION A. New construction, conversion to, and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated at a minimum of one (1) foot above the Base Flood Elevation (BFE). ... A. New construction, conversion to, and substantial improvement of any commercial, industrial, or other non-residential structure shall: 1. Have the lowest floor, including basement, elevated at or above the Base Flood Elevation (BFE) or ... B. The bottom of the longitudinal chassis frame beam shall be at or above Base Flood Elevation. ... A. All new construction and substantial improvements in Zones V1-V30 and VE, V, and coastal A zones (where base flood elevation data is available) shall be elevated on pilings and columns such that: ... 1. The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated a minimum of one foot above the base flood level; and
Full Breakdown
The elevation standards sit in Ordinance No. 2025-04, which repealed and replaced Chapter 152. For residential structures in riverine (non-coastal) Zones A1-A30, AH and AE, § 152.5.2.3.2 requires new construction, conversion and substantial improvement to have the lowest floor, including basement, elevated at a minimum of one foot above the Base Flood Elevation (BFE). The ordinance defines BFE as the elevation to which floodwater is anticipated to rise during the base flood, and the base flood as the flood with a one percent chance of being equaled or exceeded in any given year. Substantial improvement means an improvement whose cost equals or exceeds 50 percent of the market value of the structure before the start of construction.
Non-residential structures in those zones must either have the lowest floor, including basement, elevated at or above the BFE, or be floodproofed so the structure is watertight below the base flood level, with walls substantially impermeable to water, structural components that resist hydrostatic and hydrodynamic loads and buoyancy, and a registered professional engineer or architect certification provided to the Floodplain Administrator (§ 152.5.2.3.3). Applicants who floodproof are told that flood insurance premiums will be rated one foot below the floodproofed level. A manufactured dwelling needs the bottom of its longitudinal chassis frame beam at or above BFE (§ 152.5.2.3.4). Enclosed areas below the lowest floor must have flood openings: a minimum of two openings, a total net area of not less than one square inch for each square foot of enclosed area, and the bottom of every opening no higher than one foot above grade (§ 152.5.2.1).
In coastal high hazard areas, Zones V1-V30, VE, V and coastal A zones where BFE data is available, § 152.5.3.1 requires new construction and substantial improvements to be elevated on pilings and columns so the bottom of the lowest horizontal structural member of the lowest floor, excluding the pilings or columns, is a minimum of one foot above the base flood level, with the foundation anchored against flotation, collapse and lateral movement. A registered professional engineer or architect must certify the design. Where no regulatory floodway is designated, no new construction or substantial improvement is permitted in Zones A1-30 and AE unless the cumulative effect will not raise the base flood water surface elevation more than one foot and will not cause a net loss of flood storage volume (§ 152.5.2.3.1).
Violations & Fines
Violating the requirements of the chapter, including the elevation standards, is a misdemeanor punishable on conviction by a fine of not more than $500.00 or imprisonment for a period not to exceed 180 days or both (§ 152.3.4.2). A variance to build below the Base Flood Elevation needs good and sufficient cause, a finding of exceptional hardship, and a finding that it will not increase flood heights or add threats to public safety (§ 152.4.4.1(D)), plus written notice that premium rates will increase (§ 152.4.4.2).
Frequently Asked Questions
How high must a new Seaside home be above flood level?
Does the elevation rule apply to remodels in Seaside?
What are the flood opening rules for enclosed areas below the lowest floor?
How are coastal Seaside buildings elevated?
Can a non-residential building in a Seaside flood zone skip elevation?