Stonecrest, GA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential freeboard
3 ft above base flood elevation
Nonresidential freeboard
1 ft above base flood elevation
No-rise limit
0.01 foot maximum BFE increase
Certification
Registered engineer/architect required
FEMA step
CLOMR/CLOMA then final LOMR within 6 months

Summary

In the City of Stonecrest, new construction and substantial improvements in the future-conditions floodplain must clear the base flood elevation by three feet for homes and one foot for nonresidential buildings, per Stonecrest Code § 14-429. Section 14-428 separately bars any development that would raise the base flood elevation by 0.01 foot or more.

No development shall be allowed within the future-conditions floodplain that could result in the following: (1)Raising the base flood elevation or future-conditions flood elevation equal to or more than 0.01 foot ... all new construction and substantial improvements shall ... have the lowest floor, including basement, elevated no lower than three (3) feet above the base flood elevation or one (1) foot above the future-conditions flood elevation, which is higher.

Full Breakdown

Two sections of the floodplain management article set Stonecrest's elevation standard. Section 14-428 imposes a 'no-rise' baseline: no development is allowed within the future-conditions floodplain that would raise the base flood elevation or future-conditions flood elevation by 0.01 foot or more, reduce base flood or future-conditions flood storage capacity, change the depth or velocity of floodwaters at the upstream or downstream boundary of the development, or create hazardous or erosion-producing velocities. Any development that clears that no-rise bar must still meet compensation, cut-slope, and utility-siting conditions in § 14-428(b), and any significant physical change to the base flood floodplain must be submitted to FEMA as a conditional letter of map revision or amendment, with the applicant responsible for FEMA follow-through and for submitting as-built surveys for a final letter of map revision within six months of completing construction.

Section 14-429 then sets the freeboard itself: once the § 14-427/14-428/14-439 study and no-rise requirements are satisfied, new construction and substantial improvements of residential principal buildings, including manufactured homes, must have the lowest floor, including the basement, elevated no lower than three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher. Nonresidential buildings need only clear one foot above the base flood elevation or the future-conditions elevation, whichever is higher, and may floodproof to that height in place of elevating, provided a registered professional engineer or architect certifies the design as watertight and structurally capable of resisting hydrostatic and hydrodynamic loads. Solid perimeter foundation walls used to elevate a structure must include flood-vent openings sized under § 14-429(b)(3)(iii) to equalize hydrostatic pressure.

Violations & Fines

Building below the required freeboard, or filling and grading that raises the base flood elevation by 0.01 foot or more in violation of § 14-428's no-rise standard, is enforced through § 14-413 as a misdemeanor, with a fine and/or imprisonment under chapter 1 of the city code and each day of noncompliance counted as a separate offense until the structure or fill is brought into compliance or removed.

Frequently Asked Questions

How high above base flood elevation must a new Stonecrest home be built?
Stonecrest Code § 14-429 requires the lowest floor, including the basement, of new construction and substantially improved residential buildings to sit at least three feet above the base flood elevation, or one foot above the future-conditions flood elevation, whichever is higher.
Can a development raise the base flood elevation at all?
Only 0.01 foot. Section 14-428 blocks any development in the future-conditions floodplain that would raise the base flood elevation or future-conditions flood elevation by 0.01 foot or more, and requires a step-backwater analysis verifying the no-rise condition before a permit issues.
Can a commercial building floodproof instead of elevating?
Yes. Section 14-429 lets nonresidential new construction and substantial improvements floodproof to at least one foot above the base flood elevation instead of physically elevating, but a registered professional engineer or architect must certify the design is watertight and can resist hydrostatic and hydrodynamic loads.

Sources & Official References

Other rules in Stonecrest

All Stonecrest rules

Compare Stonecrest to another location·View the Georgia environmental rules overview

Get notified when Flood Elevation Requirements in Stonecrest, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.