Trenton, NJ Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Governing section
- City Code § 109-17
- Freeboard required
- Base flood elevation + 3 feet
- Applies in
- A / AE flood zones
- Floodway rise cap
- 0.2 foot, § 109-18C
- Certification
- Licensed engineer/architect, nonresidential
Summary
New and substantially improved residential structures in Trenton's A or AE flood zones must have their lowest floor, including basement, elevated to the base flood elevation plus three feet of freeboard. Nonresidential buildings must meet the same elevation or be engineer-certified as floodproofed to that height.
New construction and substantial improvement of any residential structure located in an A or AE Zone shall have the lowest floor, including basement, together with the attendant utilities and sanitary facilities, elevated at or above the base flood elevation plus three feet or as required by ASCE/SEI 24-14, Table 2-1, whichever is more restrictive... In an area of special flood hazard, all new construction and substantial improvement of any commercial, industrial or other nonresidential structure located in an A or AE Zone... shall have the lowest floor... elevated to or above the base flood elevation plus three feet or as required by ASCE/SEI 24-14, Table 6-1, whichever is more restrictive.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4853025; v21 updated 2025-12-16; through 12-16-2025).
Full Breakdown
City Code § 109-17, Specific standards, applies in all areas of special flood hazard where base flood elevation data has been provided under § 109-7 or § 109-14B. For residential construction in an A or AE Zone, § 109-17A(2) requires the lowest floor, including any basement, along with attendant utilities and sanitary facilities, elevated at or above the base flood elevation plus three feet of freeboard, or as required by ASCE/SEI 24-14, Table 2-1, whichever is more restrictive. In AO or AH Zones, the lowest floor must sit above the mapped shallow-flooding depth number plus three feet above the highest adjacent grade, with drainage paths required around structures on slopes.
Nonresidential buildings in A or AE Zones face the same three-foot freeboard elevation standard under § 109-17B, or as an alternative may be floodproofed watertight up to that same height with walls substantially impermeable to water, structural components able to resist hydrostatic and hydrodynamic loads, and certification by a registered professional engineer or architect that the design meets accepted practice. Manufactured homes placed or substantially improved in a special flood hazard area must likewise be anchored per § 109-16A(2) and elevated on a permanent foundation so the top of the lowest floor sits at or above base flood elevation plus three feet. 2 foot where no floodway is designated.
Violations & Fines
Constructing or substantially improving a structure below the required elevation, or without the engineer certification § 109-17B(1)(e) demands for floodproofed nonresidential buildings, is a violation of Chapter 109 punishable under § 109-8 by a fine of up to $2,000, imprisonment of up to 30 days, or both, per violation.
Frequently Asked Questions
How high above the base flood elevation must my home's lowest floor be in Trenton?
Can a commercial building be floodproofed instead of elevated?
Is there a limit on how much new development can raise flood levels in Trenton?
Sources & Official References
Other rules in Trenton
Compare Trenton to another location·View the New Jersey environmental rules overview