Key Facts

Required freeboard
2.0 feet above BFE
Applies to
Zones A and AE, new/substantial work
Mechanical equipment
Also elevated 2.0 feet above BFE
No-BFE default
2 feet above highest adjacent grade
Amended
April 11, 2023

Summary

West Hartford requires 2.0 feet of freeboard above the base flood elevation (BFE) in Town Code § 177-8: new construction and substantial improvements in Zones A and AE must have their lowest floor, including basement, and all mechanical equipment elevated that far above the BFE published in FEMA's Flood Insurance Study.

BASE FLOOD ELEVATION (BFE) The elevation of the crest of the base flood or one-hundred-year flood. The height in relation to mean sea level expected to be reached by the waters of the base flood at pertinent points in the floodplains of coastal and riverine areas. ... Construction standards in special flood hazard areas (SFHA) Zones A and AE for residential and nonresidential construction. All new construction and substantial improvements of structures shall have the bottom of the lowest floor, including basement, elevated 2.0 feet above the base flood elevation (BFE) [CFR 60.3(c)(2) and (3)]. The bottom of all electrical, heating, plumbing, ventilation and air-conditioning equipment, appliances, fixtures and components, HVAC duct work and duct systems, and any other utility service equipment, facilities, machinery, or connections servicing a structure shall be elevated 2.0 feet above the base flood elevation (BFE).

Full Breakdown

Section 177-8 defines the base flood elevation (BFE) as the height in relation to mean sea level expected to be reached by the base, or one-hundred-year, flood at a given point, drawing from FEMA's Flood Insurance Study and Flood Insurance Rate Map. The specific construction standard then goes beyond that baseline: in SFHA Zones A and AE, all new construction and substantial improvements of residential and nonresidential structures must have the bottom of the lowest floor, including any basement, elevated 2.0 feet above the BFE, referencing 44 CFR 60.3(c)(2) and (3).

The same 2.0-foot freeboard applies to every piece of utility equipment servicing the structure, including furnaces, oil or propane tanks, air conditioners, heat pumps, hot water heaters, ventilation duct work, washer and dryer hookups, electrical junction boxes and circuit breaker boxes, so mechanical rooms cannot sit at grade even if the living space is elevated. Manufactured homes placed or substantially improved in an SFHA must likewise have the bottom of the frame of the lowest floor 2.0 feet above the BFE on a securely anchored permanent foundation.

Where no BFE has been established for a watercourse, the Director of Community Development must obtain data from federal, state or other sources, and absent any BFE the lowest floor must still be elevated two feet above the highest adjacent grade next to the structure. These freeboard standards were amended April 11, 2023, and are enforced through the same $100-per-day penalty and development-application review described in § 177-8's general floodplain provisions.

Violations & Fines

Failure to meet the 2.0-foot freeboard standard is treated as noncompliant floodplain development under § 177-8, subject to the section's $100-per-day fine for each day the violation continues, and the Director of Community Development will not certify a noncompliant plan, so no building permit can issue until the required elevation is documented.

Frequently Asked Questions

How much freeboard does West Hartford require above base flood elevation?
Section 177-8 requires the lowest floor, including any basement, of new construction and substantial improvements in Zones A and AE to be elevated 2.0 feet above the base flood elevation, and the same 2.0-foot freeboard applies to all servicing utility equipment.
Do HVAC and electrical systems need to be elevated too?
Yes. Section 177-8 elevates the bottom of all electrical, heating, plumbing, ventilation and air-conditioning equipment, appliances, fixtures, duct work and circuit breaker boxes servicing a structure to 2.0 feet above the base flood elevation, not just the living space.
What if no base flood elevation has been published for my watercourse?
Where BFE and floodway data have not been established, the Director of Community Development must obtain available data, and if no BFE can be determined, the lowest floor including basement must still be elevated two feet above the highest adjacent grade next to the structure.

Sources & Official References

Other rules in West Hartford

All West Hartford rules

Compare West Hartford to another location·View the Connecticut environmental rules overview

Get notified when Flood Elevation Requirements in West Hartford, CT changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.