Skip to main content
CityRuleLookup

Wylie, TX Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
Lowest floor 2 feet above base flood elevation
Certification
Registered engineer or land surveyor to floodplain administrator
Enclosure vents
1 sq in per sq ft, minimum two openings
Manufactured homes
Same 2-foot freeboard plus anchoring
Administrator
City engineer or city manager's designee

Summary

In the City of Wylie, new and substantially improved residential structures inside a mapped Special Flood Hazard Area must have the lowest floor built at least two feet above the base flood elevation. Nonresidential buildings can meet the same two-foot freeboard or be floodproofed instead. A registered engineer or surveyor must certify compliance to the floodplain administrator before occupancy.

(1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated at least two feet above the base flood elevation. A registered professional engineer or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 50-108(a)(1), is satisfied.

Full Breakdown

Section 50-132 of the Wylie Code of Ordinances sets the specific flood-hazard-reduction standards that apply once base flood elevation data exists for a site under section 50-79, section 50-107(8) or section 50-133(c). For residential construction, the lowest floor, including any basement, must sit at least two feet above the base flood elevation, and a registered professional engineer or land surveyor must certify to the floodplain administrator that the structure meets the standard described in the section 50-108(a)(1) permit application. Nonresidential buildings get an alternative: they may either meet the same two-foot freeboard or be floodproofed below that level with watertight, substantially impermeable walls and structural components able to resist hydrostatic and hydrodynamic loads, certified by a registered engineer or architect.

Enclosed areas below the lowest floor used only for parking, building access or storage must have at least two flood openings on separate walls totaling one square inch of net area per square foot of enclosed space, with the bottom of each opening no higher than one foot above grade. Manufactured homes placed in mapped Zones A1-30, AH and AE outside an existing park must also be elevated so the lowest floor clears the base flood elevation by two feet and be anchored against flotation and lateral movement.

The city engineer or the city manager's designated representative administers these standards as floodplain administrator under section 50-106, and every application runs through the permit process in section 50-108.

Violations & Fines

Occupying or completing new construction, a substantial improvement, or a manufactured home installation below the required two-foot freeboard without the section 50-108(a)(1) engineer or surveyor certification is a violation of section 50-132 and section 50-136's compliance mandate, enforceable under the general penalty in section 1-13, up to $2,000.00 per offense with each day of noncompliance a separate offense.

Frequently Asked Questions

How high above the base flood elevation must a Wylie home be built?
Section 50-132(1) requires the lowest floor, including any basement, of new construction or a substantial improvement to sit at least two feet above the base flood elevation. A registered professional engineer or land surveyor must certify to the floodplain administrator that the elevation meets this standard before the section 50-108 permit is finalized.
Can a commercial building in the floodplain skip the elevation requirement?
Yes, if it is floodproofed instead. Section 50-132(2) lets nonresidential structures either meet the same two-foot freeboard or be built watertight below that level, with walls substantially impermeable to water and structural components rated to resist flood loads, all certified by a registered engineer or architect and recorded with the floodplain administrator.
What about a garage or storage area below the elevated floor?
Section 50-132(3) requires enclosed areas below the lowest floor used only for parking, building access or storage to have at least two openings on separate walls, sized to one square inch of net area for every square foot of enclosed space, with the bottom of each opening no higher than one foot above grade.

Sources & Official References

Other rules in Wylie

All Wylie rules

Texas rules heatmap·Compare Wylie to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Wylie, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Collin County handle flood elevation requirements.

Allen, TX
Some Restrictions
Frisco, TX
Some Restrictions
McKinney, TX
Some Restrictions
Plano, TX
Significant Restrictions