Key Facts
- Freeboard required
- Lowest floor 2 feet above base flood elevation
- Certification
- Registered engineer or land surveyor to floodplain administrator
- Enclosure vents
- 1 sq in per sq ft, minimum two openings
- Manufactured homes
- Same 2-foot freeboard plus anchoring
- Administrator
- City engineer or city manager's designee
Summary
In the City of Wylie, new and substantially improved residential structures inside a mapped Special Flood Hazard Area must have the lowest floor built at least two feet above the base flood elevation. Nonresidential buildings can meet the same two-foot freeboard or be floodproofed instead. A registered engineer or surveyor must certify compliance to the floodplain administrator before occupancy.
(1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated at least two feet above the base flood elevation. A registered professional engineer or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 50-108(a)(1), is satisfied.
Full Breakdown
Section 50-132 of the Wylie Code of Ordinances sets the specific flood-hazard-reduction standards that apply once base flood elevation data exists for a site under section 50-79, section 50-107(8) or section 50-133(c). For residential construction, the lowest floor, including any basement, must sit at least two feet above the base flood elevation, and a registered professional engineer or land surveyor must certify to the floodplain administrator that the structure meets the standard described in the section 50-108(a)(1) permit application. Nonresidential buildings get an alternative: they may either meet the same two-foot freeboard or be floodproofed below that level with watertight, substantially impermeable walls and structural components able to resist hydrostatic and hydrodynamic loads, certified by a registered engineer or architect.
Enclosed areas below the lowest floor used only for parking, building access or storage must have at least two flood openings on separate walls totaling one square inch of net area per square foot of enclosed space, with the bottom of each opening no higher than one foot above grade. Manufactured homes placed in mapped Zones A1-30, AH and AE outside an existing park must also be elevated so the lowest floor clears the base flood elevation by two feet and be anchored against flotation and lateral movement.
The city engineer or the city manager's designated representative administers these standards as floodplain administrator under section 50-106, and every application runs through the permit process in section 50-108.
Violations & Fines
Occupying or completing new construction, a substantial improvement, or a manufactured home installation below the required two-foot freeboard without the section 50-108(a)(1) engineer or surveyor certification is a violation of section 50-132 and section 50-136's compliance mandate, enforceable under the general penalty in section 1-13, up to $2,000.00 per offense with each day of noncompliance a separate offense.
Frequently Asked Questions
How high above the base flood elevation must a Wylie home be built?
Can a commercial building in the floodplain skip the elevation requirement?
What about a garage or storage area below the elevated floor?
Sources & Official References
Other rules in Wylie
Texas rules heatmap·Compare Wylie to another location·View the Texas environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in Collin County handle flood elevation requirements.