St. Martin Parish, LA Environmental Rules: Stormwater Management (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified November 2026

Key Facts

Subsurface storm sewers
Designed for a minimum ten-year storm
Channel crossings over 100 square feet
Designed for a 25-year storm
Runoff method under 200 acres
Rational method (Q=ciA)
Runoff method, 200 to 2,000 acres
SCS Method as modified by DOTD
Runoff method over 2,000 acres
USGS regression procedure
Lateral drainage servitude
Minimum 15 feet subsurface; 20 feet for open ditch

Summary

Developments in unincorporated St. Martin Parish, Louisiana must be drained to numeric storm standards set in St. Martin Parish Code § 14-102. Subsurface storm sewers are designed for a minimum ten-year storm, channel crossings over 100 square feet for a 25-year storm, and the engineer picks the runoff method by drainage area, with breakpoints at 200 acres and 2,000 acres.

These county ordinances apply to unincorporated areas of St. Martin Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(b)Runoff determination methods. For drainage areas less than 200 acres, the design engineer shall use the rational method (Q=ciA) procedure for determining runoff rates. For drainage areas between 200 and 2,000 acres, the design engineer shall use the most recent Soil Conservation Service (SCS) Method, as modified by the state department of transportation and development (DOTD) procedure for determining runoff rates. For drainage areas greater than 2,000 acres, the design engineer shall use the most recent USGS regression procedure for determining runoff rates.(c)Drainage design criteria. Subsurface storm sewer systems for developments shall be designed for a minimum ten-year storm. Storm sewers for outfall channels shall be designed for a ten-year storm (minimum). Developments with open ditch drainage systems shall be designed for a storm of ten year occurrence interval. Cross drains for drainage channels within developments shall be designed for a ten-year storm. Channel crossings in excess of 100 square feet shall be designed for a 25-year storm. Drainage designs shall be in conformance with the latest edition of the state DOTD hydraulics manual.

Full Breakdown

Section 14-102 sits in Article IV of the flood chapter, Development Drainage Detention, which Ord. No. 19-12-1282-OR enacted on December 3, 2019. Subsection (a)(1) puts the burden on the developer's design engineer: provide in the drainage improvements for runoff from the entire upstream drainage area, whether inside or outside the development, and study the effect on existing downstream drainage facilities or roadside ditches. If the runoff will overload one, the engineer must say so in the drainage impact analysis and make provision to prevent the overload. Existing natural and artificial channels shall not be incorporated into or function as a proposed storm water management facility.

Subsection (b) picks the runoff method by drainage area: the rational method for areas under 200 acres, the SCS method as modified by DOTD for areas between 200 and 2,000 acres, and the USGS regression procedure above 2,000 acres. Subsection (c) sets the storms: a minimum ten-year storm for subsurface storm sewers and outfall channel sewers, a ten year occurrence interval for open ditch systems, a ten-year storm for cross drains, and a 25-year storm for channel crossings in excess of 100 square feet. Rainfall intensity and duration come from the latest DOTD hydraulics manual under subsection (d), and the rational method coefficients are printed in tables 4.1 and 4.2, such as 0.30 to 0.50 for single-family detached and 0.40 to 0.60 for two-family (duplex).

Plan content is also fixed. Section 14-102(a)(2) requires drainage plans with benchmarks, NGVD elevations, annotated culverts, hydraulic calculations and drainage area maps, and puts a lateral drainage conduit from the street to an outfall channel across lots in a minimum 15-foot permanent drainage servitude, or 20 feet for approved open ditch drainage. Under Sec. 14-101(5)(a), a comprehensive drainage impact analysis goes to the parish after preliminary plat approval, construction plans are not approved until the parish approves it, and a developer can ask in writing for a waiver. Separately, Sec. 8-31 prohibits discharging anything other than stormwater into the MS4, with listed exemptions such as water line flushing and landscape irrigation. Chapter 8 article III (2014) still prints its own drainage criteria at §§ 8-100 to 8-104, including a five year storm for subsurface storm sewers, so ask the parish Planning and Development office which text controls a given plat.

Violations & Fines

Chapter 8 article II, which covers stormwater runoff and discharges to the MS4, is enforced by notice of violation, administrative orders and court action. Under Sec. 8-83, the parish attorney can seek civil penalties not exceeding $1000.00 per violation per day, and a willful or malicious violation is a misdemeanor punishable by a fine not exceeding $1000.00 and/or imprisonment for not more than 30 days for each violation. Under Sec. 14-101(5)(a)(3), construction begun before the drainage impact analysis is approved can bring a cease and desist order.

Frequently Asked Questions

What design storm applies to storm sewers in a new development?
Section 14-102(c) requires subsurface storm sewer systems for developments to be designed for a minimum ten-year storm, and storm sewers for outfall channels for a ten-year storm minimum. Developments with open ditch systems use a storm of ten year occurrence interval, cross drains use a ten-year storm, and channel crossings in excess of 100 square feet use a 25-year storm.
How does the engineer calculate runoff?
Section 14-102(b) sets the method by drainage area. Below 200 acres the design engineer uses the rational method (Q=ciA). Between 200 and 2,000 acres the engineer uses the most recent SCS Method as modified by DOTD. Above 2,000 acres the engineer uses the most recent USGS regression procedure. Rainfall intensity and duration come from the latest DOTD hydraulics manual.
Is a drainage impact analysis required before construction?
Under Sec. 14-101(5)(a), a comprehensive drainage impact analysis of the development and surrounding affected areas goes to the parish after preliminary plat approval, and construction plans are not approved until the analysis is approved. A developer can submit a written waiver request, and the parish grants it only by written approval after a favorable evaluation of the conditions.
Can I send pool water or car wash water to the storm drain?
Section 8-31 prohibits discharging into the MS4 anything other than stormwater, but exempts listed discharges, including non-commercial washing of vehicles, landscape irrigation or lawn watering, firefighting activities and swimming pools if dechlorinated. Connecting a line that conveys sewage to the stormwater system is a separate violation under Sec. 8-32.

Sources & Official References

Other rules in St. Martin Parish

All St. Martin Parish rules

Compare St. Martin Parish to another location·View the Louisiana environmental rules overview

Get notified when Stormwater Management in St. Martin Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.