Skip to main content
CityRuleLookup

Tazewell County, IL Fire Regulations: Propane Storage (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Liquid-form LP-gas piping indoors
prohibited
Vaporizing by open flame/coil
prohibited
Containers
need pressure-relief safety devices
System shutoff
required, kept operable
Penalty
up to $1,000 per day
Enforcing agency
Director of Public Health

Summary

Section 96.08(EE) of the county's Human Habitation chapter bars piping liquid-form propane through buildings, bans vaporizing it with open flame or electrical coil, and requires LP-gas containers to be sited so they aren't a hazard, fitted with pressure-relief safety devices, and equipped with an accessible shutoff.

These county ordinances apply to unincorporated areas of Tazewell County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(EE) Undiluted liquefied petroleum gas in liquid form shall not be conveyed through piping equipment and systems in buildings. Liquefied petroleum gas shall not be vaporized by devices utilizing open flame or open electrical coil. Where two or more containers are installed, connection shall be arranged so that containers can be replaced without shutting off the flow of gas to equipment. Containers shall be designed, stored, and located so as not to be a hazard to the premises served or to the surrounding property. Systems shall be provided with safety devices to relieve excessive pressures and shall be arranged so that the discharge terminates at a safe location. Systems shall have at least one accessible means for shutting off the gas. Such means shall be in good operating condition.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-7: Supplement contains: Local legislation current through Ord. LU-21-12, passed 9-29-2021; and Res. LU-26-09, passed 7-29-2026).

Full Breakdown

08(EE), part of the Human Habitation chapter's minimum standards for residential premises in the unincorporated county. The section prohibits conveying undiluted liquefied petroleum gas in liquid form through piping equipment and systems inside buildings, and bans vaporizing LP-gas using devices with an open flame or open electrical coil. Where a dwelling has two or more LP-gas containers, the piping connections must let a container be swapped out without shutting off gas flow to the appliances it feeds. Containers themselves must be designed, stored, and located so they don't create a hazard to the premises they serve or to surrounding property, and the system must include safety devices that relieve excessive pressure, arranged so the discharge vents to a safe location.

Every LP-gas system must also have at least one accessible means of shutting off the gas supply, and that shutoff has to be kept in good operating condition. 08(FF), separately requires that heat-producing equipment installed near combustible material be positioned, insulated, and clearance-controlled so the surface temperature of that material never reaches an unsafe level. 02, in unincorporated Tazewell County.

Violations & Fines

Violating the LP-gas storage standards in § 96.08(EE), like any Chapter 96 minimum-standards violation, is a petty offense under § 96.99 punishable by a fine of up to $1,000 for each day the condition continues uncorrected, enforced by the county's Director of Public Health.

Frequently Asked Questions

Can propane be piped through a house as a liquid?
No. Section 96.08(EE) prohibits conveying undiluted liquefied petroleum gas in liquid form through piping equipment and systems inside buildings; it must be vaporized before distribution, and not by an open flame or electrical coil.
Where must LP-gas containers be located?
They must be designed, stored, and located so they are not a hazard to the premises served or to surrounding property, and the system needs safety devices to relieve excessive pressure that vent to a safe location, per § 96.08(EE).
Is a shutoff valve required for a home propane system?
Yes. Section 96.08(EE) requires at least one accessible means of shutting off the gas supply, and that shutoff must be maintained in good operating condition.

Sources & Official References

Other rules in Tazewell County

All Tazewell County rules

Compare Tazewell County to another location·View the Illinois fire regulations overview

Get notified when Propane Storage in Tazewell County, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.