Tazewell County, IL Fire Regulations: Propane Storage (2026)
Key Facts
- Liquid-form LP-gas piping indoors
- prohibited
- Vaporizing by open flame/coil
- prohibited
- Containers
- need pressure-relief safety devices
- System shutoff
- required, kept operable
- Penalty
- up to $1,000 per day
- Enforcing agency
- Director of Public Health
Summary
Section 96.08(EE) of the county's Human Habitation chapter bars piping liquid-form propane through buildings, bans vaporizing it with open flame or electrical coil, and requires LP-gas containers to be sited so they aren't a hazard, fitted with pressure-relief safety devices, and equipped with an accessible shutoff.
(EE) Undiluted liquefied petroleum gas in liquid form shall not be conveyed through piping equipment and systems in buildings. Liquefied petroleum gas shall not be vaporized by devices utilizing open flame or open electrical coil. Where two or more containers are installed, connection shall be arranged so that containers can be replaced without shutting off the flow of gas to equipment. Containers shall be designed, stored, and located so as not to be a hazard to the premises served or to the surrounding property. Systems shall be provided with safety devices to relieve excessive pressures and shall be arranged so that the discharge terminates at a safe location. Systems shall have at least one accessible means for shutting off the gas. Such means shall be in good operating condition.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-7: Supplement contains: Local legislation current through Ord. LU-21-12, passed 9-29-2021; and Res. LU-26-09, passed 7-29-2026).
Full Breakdown
08(EE), part of the Human Habitation chapter's minimum standards for residential premises in the unincorporated county. The section prohibits conveying undiluted liquefied petroleum gas in liquid form through piping equipment and systems inside buildings, and bans vaporizing LP-gas using devices with an open flame or open electrical coil. Where a dwelling has two or more LP-gas containers, the piping connections must let a container be swapped out without shutting off gas flow to the appliances it feeds. Containers themselves must be designed, stored, and located so they don't create a hazard to the premises they serve or to surrounding property, and the system must include safety devices that relieve excessive pressure, arranged so the discharge vents to a safe location.
Every LP-gas system must also have at least one accessible means of shutting off the gas supply, and that shutoff has to be kept in good operating condition. 08(FF), separately requires that heat-producing equipment installed near combustible material be positioned, insulated, and clearance-controlled so the surface temperature of that material never reaches an unsafe level. 02, in unincorporated Tazewell County.
Violations & Fines
Violating the LP-gas storage standards in § 96.08(EE), like any Chapter 96 minimum-standards violation, is a petty offense under § 96.99 punishable by a fine of up to $1,000 for each day the condition continues uncorrected, enforced by the county's Director of Public Health.
Frequently Asked Questions
Can propane be piped through a house as a liquid?
Where must LP-gas containers be located?
Is a shutoff valve required for a home propane system?
Sources & Official References
Other rules in Tazewell County
Compare Tazewell County to another location·View the Illinois fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.