Tazewell County, IL Fire Regulations: Smoke Detectors (2026)
Key Facts
- Detector required
- within 15 ft of every sleeping room
- Single-family homes
- one detector per story
- Multi-unit buildings
- detector atop each stairwell
- Post-1987 construction
- hardwired, interconnected detectors
- Battery duty
- owner installs, tenant maintains
- Penalty
- up to $1,000 per day
Summary
Section 96.09 requires every dwelling unit to have a working smoke detector within 15 feet of every bedroom, plus one on every story including basements. New construction after 1987 needs hardwired, interconnected detectors; older units may use battery power. Owners install, tenants maintain.
(A) Every dwelling unit shall be equipped with at least one approved smoke detector in an operating condition within 15 feet of every room used for sleeping purposes. The detector shall be installed on the ceiling and at least six inches from any wall, or on a wall located between four and six inches from the ceiling. (B) Every single family residence shall have at least one approved smoke detector installed on every story of the dwelling unit, including basements but not including unoccupied attics.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-7: Supplement contains: Local legislation current through Ord. LU-21-12, passed 9-29-2021; and Res. LU-26-09, passed 7-29-2026).
Full Breakdown
09. Division (A) mandates at least one approved smoke detector, in operating condition, within 15 feet of every room used for sleeping, mounted on the ceiling at least six inches from any wall or on a wall between four and six inches from the ceiling. Division (B) additionally requires every single-family residence to have at least one detector on every story, including basements but not unoccupied attics; in split-level homes a detector on the upper level covers the adjacent lower level unless there's an intervening door, in which case each level needs its own.
Division (C) requires structures with more than one dwelling unit, or mixed-use buildings with at least one dwelling unit, to have a detector at the uppermost ceiling of every interior stairwell. Under division (D), the owner must supply and install all required detectors and maintain those in common stairwells and hallways, while tenants test and maintain the detector in their own unit, replace its batteries, and must notify the owner in writing of any deficiency they can't fix themselves. Detectors in any dwelling unit existing on July 1, 1988 may be battery-powered or wired into house current and need not be interconnected, per division (E); but under division (F), any unit newly built, reconstructed, or substantially remodeled after December 31, 1987 must have detectors permanently wired into the AC power line, interconnected so that one alarm triggers all of them.
Violations & Fines
Failing to install or maintain the required smoke detectors under § 96.09 is a petty offense under § 96.99, carrying a fine of up to $1,000 for each day the violation continues, enforced by the county's Director of Public Health.
Frequently Asked Questions
How close must a smoke detector be to a bedroom in Tazewell County?
Are hardwired smoke detectors required in older Tazewell County homes?
Who is responsible for replacing smoke detector batteries, the landlord or tenant?
Sources & Official References
Other rules in Tazewell County
Compare Tazewell County to another location·View the Illinois fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.