De Pere, WI Fire Regulations: Smoke Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopted standard
Wis. Admin. Code ch. SPS 328
Adopting section
De Pere Code § 54-3(a)(1)h
Applies to
New builds, additions, alterations, pre-1980 homes
Also covers
Detached garages and accessory buildings
Enforced by
City building inspector at permit inspections
Record on file
Kept at office of city building inspector

Summary

De Pere folds the state's smoke and carbon monoxide detector rules straight into its own building code. Sec. 54-3(a)(1)h adopts Wis. Admin. Code ch. SPS 328 by reference, and Sec. 54-3(c) extends it to new construction, additions, alterations, and even pre-1980 homes, garages and accessory buildings when they are worked on.

(1)The following provisions of the Wisconsin Administrative Code, collectively constituting the state uniform dwelling code, are adopted by reference and made part of this chapter as if fully set forth in this chapter: ... h.Wis. Admin. Code ch. SPS 328, Smoke detectors and carbon monoxide detectors. ... (c)Applicability. The Wisconsin Administrative Codes, as adopted in this chapter, are intended to apply to additions and alterations to one-family and two-family dwellings, including existing one-family and two-family dwellings, which were built prior to June 1, 1980 (effective adoption date of the uniform dwelling code), detached garages, accessory buildings, as well as new construction.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 9).

Full Breakdown

Sec. 54-3(a) of the Code of Ordinances lists eight chapters of the Wisconsin Administrative Code that together make up the state uniform dwelling code adopted for De Pere, and item h names 'Wis. Admin. Code ch. SPS 328, Smoke detectors and carbon monoxide detectors' specifically. Sec. 54-3(a)(2) makes clear the adoption is not symbolic: any act the state chapter requires or prohibits is 'required or prohibited by this chapter,' so a missing or nonfunctioning detector is a City Code violation, not merely a state one.

Sec. 54-3(c) fixes how far the detector duty reaches: it applies to new one- and two-family construction, to additions and alterations of existing one- and two-family dwellings, including dwellings built before June 1, 1980, the effective date of the uniform dwelling code, and it reaches detached garages and accessory buildings as well. Sec. 54-3(d) puts enforcement with the building inspector or any inspector of the building inspection division, who is authorized to enter the premises at reasonable hours, as a condition of the building permit, during construction and until final inspection and approval, to check compliance with all state and municipal codes in this chapter, meaning SPS 328 compliance is checked at the same rough and final inspections that clear the rest of the dwelling.

A copy of SPS 328 and any future amendments must be kept on file in the office of the city building inspector under Sec. 54-3(a)(2), so a homeowner or contractor can review the exact placement and testing standard the city is enforcing before scheduling an inspection.

Violations & Fines

Chapter 54 attaches no detector-specific fine, so a violation of the adopted SPS 328 standard falls under the Code's general forfeiture in Sec. 1-11(a): not less than $1.00 nor more than $2,000.00 for each offense, rising to $10.00-$2,000.00 for a repeat offense under Sec. 1-11(b). Because compliance is checked at rough and final inspection under Sec. 54-3(d), a missing or defective detector can also hold up the certificate of occupancy required by Sec. 54-3(f)(9) before the dwelling may be used.

Frequently Asked Questions

Does De Pere have its own smoke detector ordinance?
Not a separate one. Sec. 54-3(a)(1)h adopts Wis. Admin. Code ch. SPS 328, Smoke Detectors and Carbon Monoxide Detectors, by reference into the city's own building code, so the state chapter is enforced as a City Code requirement, not just a state one.
Do older De Pere homes have to meet the detector code?
Yes, when worked on. Sec. 54-3(c) applies the adopted uniform dwelling code, including SPS 328, to additions and alterations of one- and two-family dwellings built before June 1, 1980, not just to new construction.
Who checks that a De Pere home has working detectors?
The building inspector or any inspector in the building inspection division. Sec. 54-3(d) authorizes them to enter the premises as a condition of the building permit, through construction and until final inspection and approval, to confirm compliance with the adopted state code.

Sources & Official References

Other rules in De Pere

All De Pere rules

Compare De Pere to another location·View the Wisconsin fire regulations overview

Get notified when Smoke Detectors in De Pere, WI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Smoke Detectors in Nearby Cities

How other cities in Brown County handle smoke detectors.

Green Bay, WI
Some Restrictions
Ashwaubenon, WI
Some Restrictions