Florissant's Property Maintenance Code requires existing Group I-1 and residential occupancies to carry single-station smoke alarms under Section 704.6.1, interconnected so one alarm triggers all of them, and powered from the building's wiring with a battery backup under Section 704.6.3.

Section 704.6.1 Where required (Amended). Existing Group I-1 and R occupancies shall be provided with single-station smoke alarms in accordance with Sections 704.6.1.1 through 704.6.1.4. Interconnection and power sources shall be in accordance with Sections 704.6.2 and 704.6.3. ... Section 704.6.3 Power source (Amended). Single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4989395; v43 updated 2026-05-26; through 05-26-2026).

Full Breakdown

3, subject only to the exception that smoke detectors already tied into a building fire alarm system can substitute for standalone alarms. 2 Interconnection requires that where more than one smoke alarm is required within a single dwelling or sleeping unit, all of them must be wired or, if listed as wireless, linked so that one activating sounds every alarm in the unit, loud enough to be heard in every bedroom with the doors closed; interconnection is not required in buildings that are not undergoing alteration, repair or construction, and existing alarms don't have to be interconnected retroactively unless the work removes interior wall or ceiling finishes.

3 Power Source requires a single-station alarm to draw its primary power from commercial building wiring plus a battery backup, with alarms that have integral strobes and no battery backup connected instead to an emergency electrical system; every alarm must chirp a low-battery signal, and the wiring must be permanent, without any disconnect switch beyond normal overcurrent protection. Purely battery-powered alarms are allowed in existing buildings with no construction underway, in buildings with no commercial power source, or in areas being altered without exposing wall or ceiling framing.

Violations & Fines

Failing to install, interconnect or properly power required smoke alarms is a violation of the Property Maintenance Code subject to the penalties of Section 100.080 under Section 109.4, with each day the condition continues after notice served treated as a separate offense.

Frequently Asked Questions

Does Florissant require interconnected smoke alarms in older homes?
Only when the home is undergoing alteration, repair or construction; Section 704.6.2 exempts buildings not undergoing any such work, and even during work, interconnection isn't required unless interior wall or ceiling finishes come off.
Can my smoke alarms run on batteries only?
Yes, in specific situations: Section 704.6.3 allows battery-only alarms in existing buildings with no construction underway, buildings without a commercial power source, or areas being altered without exposing the wall or ceiling framing.
What powers a hardwired smoke alarm in Florissant?
Section 704.6.3 requires primary power from the building's commercial wiring plus a battery backup, and every alarm must emit a signal when that battery runs low, so residents know to replace it before the backup fails.

Sources & Official References

Other rules in Florissant

All Florissant rules

Compare Florissant to another location·View the Missouri fire regulations overview

Get notified when Smoke Detectors in Florissant, MO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.