Key Facts

Bedrooms
Smoke detector in each bedroom
Hallways
Detector outside each bedroom in common hallways
Floors
Detector on each floor, including the basement
Kitchen
Fire extinguisher installed and maintained per NFPA 10
Inspection
Code Enforcement Officer or designee before approval
Maximum fine
Not to exceed $1,000 per violation

Summary

In Millcreek Township, Pennsylvania, every limited lodging (short-term rental) must have smoke detectors in each bedroom, outside each bedroom in common hallways, and on each floor including the basement. The requirement is in § 70-105(C) and is checked at the Code Enforcement Officer's inspection before a permit is approved or renewed.

C. A limited lodging shall be equipped with the following: (1) Smoke detectors in each bedroom; (2) Smoke detectors outside each bedroom in common hallways; (3) Smoke detectors on each floor, including the basement;

Full Breakdown

The Millcreek Township Limited Lodging Ordinance, Chapter 70, Part 8 of the Township Code, lists the safety equipment a rental must carry. Smoke detectors come first: one in each bedroom, one outside each bedroom in common hallways, and one on each floor, including the basement. Each of the three placements is its own line item in the list.

The same subsection also requires ground fault circuit interrupter outlets for receptacles within six feet of a water source and in all laundry facilities, a dryer exhaust system in accordance with the manufacturer's instructions, a kitchen fire extinguisher installed and maintained under the Part and NFPA 10, stairs in good condition, and a legible E-911 address marker with numerals not less than four inches in height.

Proof comes at two points. Under § 70-103(D)(6), the permit application must include proof that the limited lodging complies with § 70-105. Under § 70-104(B), a permit or renewal is approved only if the dwelling unit has passed an inspection from the Code Enforcement Officer or designee and the premises complies with the International Fire Code and the International Property Maintenance Code as adopted by the Township in Chapter 29, Parts 4 and 5. The owner consents to inspection as a condition of the permit, and § 70-105(A)(7) requires a posted notice that Millcreek Township officials can inspect the premises at any time.

The Part defines a bedroom as a room of at least 70 square feet, or at least 100 square feet if occupied by more than one person, with egress complying with the International Residential Code. That definition governs which rooms count as bedrooms for the detector requirement. Section 70-107(B) adds that the permit is not a warranty that the premises is lawful, safe, habitable, or in compliance with the Part.

The Part applies in the MU-1, MU-2 and PI Districts and the Limited Lodging Overlay. This page covers the limited lodging standard only, not the smoke alarm provisions of the adopted fire and property maintenance codes.

Violations & Fines

A rental without the listed detectors cannot satisfy the inspection condition in § 70-104(B), which puts the permit at risk of denial or revocation. Every provision of the Part is a permit condition, and a violation is punishable on summary conviction by a fine not to exceed $1,000 per violation plus court costs and reasonable attorney's fees, with each day a separate offense (§ 70-109(B)). Failing to cure within 30 days of a warning or citation is a ground for revocation.

Frequently Asked Questions

Where must smoke detectors go in a Millcreek Township short-term rental?
Section 70-105(C) requires smoke detectors in each bedroom, outside each bedroom in common hallways, and on each floor, including the basement. All three placements are listed separately, and the Code Enforcement Officer checks them at the inspection that precedes permit approval or renewal.
Does the Township inspect for smoke detectors before issuing the permit?
Yes. Under § 70-104(B), a permit is approved only if the dwelling unit has passed an inspection from the Code Enforcement Officer or designee. The owner agrees to inspections as a condition of the permit, and the application must carry proof of compliance with the § 70-105 standards.
What else does § 70-105(C) require besides smoke detectors?
It also lists ground fault circuit interrupter outlets within six feet of a water source and in laundry facilities, a dryer exhaust system installed per the manufacturer's instructions, a kitchen fire extinguisher per NFPA 10, stairs in good condition, and an E-911 address marker with numerals at least four inches high.
Does this rule apply to every rental in Millcreek Township?
It applies to limited lodging, which Part 8 limits to dwelling units in the MU-1, MU-2 and PI Districts or the Limited Lodging Overlay. Campgrounds, hotels, in-law apartments, motels, bed-and-breakfast inns and group residence facilities are excluded from the Part under § 70-99.

Sources & Official References

Other rules in Millcreek

All Millcreek rules

Compare Millcreek to another location·View the Pennsylvania fire regulations overview

Get notified when Smoke Detectors in Millcreek, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Smoke Detectors in Nearby Cities

How other cities in this county handle smoke detectors.

Erie, PA
Some Restrictions