Tinley Park, IL Fire Regulations: Smoke Detectors (2026)
Key Facts
- Detector type
- Dual voltage 120V with battery back-up
- Wiring
- Wired in series, all levels and bedrooms
- Battery mandate
- 10-year sealed battery on new alarms
- Heating-area detector
- 120V unit near heating units in attics/crawlspaces
- Governing section
- Village Code § 155.07(E)(2)
Summary
Tinley Park's electrical code requires dual-voltage, battery-backup smoke detectors wired in series on every level and in every bedroom, going beyond baseline state rules. New alarms installed after Public Act 100-0200 must carry a sealed 10-year battery.
A. Smoke detectors shall be installed in accordance with State of Illinois requirements, with the addition of: 1. Smoke detectors shall be dual voltage type (120V with battery back-up) and wired in series are required on all levels, and in every bedroom. Pursuant to State of Illinois Statutes (425 ILCS 60/ & Public Act 100-0200), any new smoke alarm being installed within a single-family residence or multi-family residence shall have a mandatory 10-year sealed battery. 2. A 120V smoke detector shall be installed in the vicinity of all heating units in normally unoccupied areas (attics, crawl spaces, basements, etc.).
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-40: Supplement contains: Local legislation current through Ordinance 2026-O-007, passed 2-17-2026, Resolution 2018-R-077, passed 10-2-18, and State legislation current through 2010 Pamphlet No. 7).
Full Breakdown
07(E)(2), Article 110 of the adopted electrical code, requires smoke detectors to be installed in accordance with State of Illinois requirements, then adds village-specific standards on top. Detectors must be dual voltage, 120V with battery back-up, and wired in series, and that requirement applies on all levels of a dwelling and in every bedroom, not just common areas. Under state law referenced directly in the section, 425 ILCS 60/ and Public Act 100-0200, any new smoke alarm installed in a single-family or multifamily residence must have a mandatory 10-year sealed battery.
The code also requires a 120V smoke detector near heating units located in normally unoccupied areas such as attics, crawl spaces, and basements, since those spaces can host a heat source without anyone present to smell smoke early. Conduits running to smoke detectors, heat detectors, and carbon monoxide detectors must be sealed to prevent condensation from interfering with the sensor. The same subsection separately requires a listed detection device in laundry rooms, interconnected with the smoke detectors, and listed heat detection in attached garages, also interconnected with the smoke alarm system.
Low-voltage fire alarm wiring run through non-accessible concealed spaces must be piped in conduit point to point, with free air in the ceiling supported by D-rings, rather than left as exposed low-voltage cable.
Violations & Fines
The section does not set a standalone dollar penalty for the smoke detector wiring and placement standards, so a violation falls to the village's general penalty at § 10.99: a fine of $50 to $750, with each day of a continuing violation treated as a separate offense. The Building Department and Electrical Inspector enforce compliance through the permit inspection process before an occupancy or electrical permit is finalized.
Frequently Asked Questions
Do Tinley Park smoke detectors need to be hardwired?
What kind of battery must a new smoke alarm have in Tinley Park?
Is a smoke detector required near the furnace in a Tinley Park home?
Sources & Official References
Other rules in Tinley Park
Compare Tinley Park to another location·View the Illinois fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Smoke Detectors in Nearby Cities
How other cities in Cook County handle smoke detectors.