Tinley Park, IL Fire Regulations: Smoke Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Detector type
Dual voltage 120V with battery back-up
Wiring
Wired in series, all levels and bedrooms
Battery mandate
10-year sealed battery on new alarms
Heating-area detector
120V unit near heating units in attics/crawlspaces
Governing section
Village Code § 155.07(E)(2)

Summary

Tinley Park's electrical code requires dual-voltage, battery-backup smoke detectors wired in series on every level and in every bedroom, going beyond baseline state rules. New alarms installed after Public Act 100-0200 must carry a sealed 10-year battery.

A. Smoke detectors shall be installed in accordance with State of Illinois requirements, with the addition of: 1. Smoke detectors shall be dual voltage type (120V with battery back-up) and wired in series are required on all levels, and in every bedroom. Pursuant to State of Illinois Statutes (425 ILCS 60/ & Public Act 100-0200), any new smoke alarm being installed within a single-family residence or multi-family residence shall have a mandatory 10-year sealed battery. 2. A 120V smoke detector shall be installed in the vicinity of all heating units in normally unoccupied areas (attics, crawl spaces, basements, etc.).

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-40: Supplement contains: Local legislation current through Ordinance 2026-O-007, passed 2-17-2026, Resolution 2018-R-077, passed 10-2-18, and State legislation current through 2010 Pamphlet No. 7).

Full Breakdown

07(E)(2), Article 110 of the adopted electrical code, requires smoke detectors to be installed in accordance with State of Illinois requirements, then adds village-specific standards on top. Detectors must be dual voltage, 120V with battery back-up, and wired in series, and that requirement applies on all levels of a dwelling and in every bedroom, not just common areas. Under state law referenced directly in the section, 425 ILCS 60/ and Public Act 100-0200, any new smoke alarm installed in a single-family or multifamily residence must have a mandatory 10-year sealed battery.

The code also requires a 120V smoke detector near heating units located in normally unoccupied areas such as attics, crawl spaces, and basements, since those spaces can host a heat source without anyone present to smell smoke early. Conduits running to smoke detectors, heat detectors, and carbon monoxide detectors must be sealed to prevent condensation from interfering with the sensor. The same subsection separately requires a listed detection device in laundry rooms, interconnected with the smoke detectors, and listed heat detection in attached garages, also interconnected with the smoke alarm system.

Low-voltage fire alarm wiring run through non-accessible concealed spaces must be piped in conduit point to point, with free air in the ceiling supported by D-rings, rather than left as exposed low-voltage cable.

Violations & Fines

The section does not set a standalone dollar penalty for the smoke detector wiring and placement standards, so a violation falls to the village's general penalty at § 10.99: a fine of $50 to $750, with each day of a continuing violation treated as a separate offense. The Building Department and Electrical Inspector enforce compliance through the permit inspection process before an occupancy or electrical permit is finalized.

Frequently Asked Questions

Do Tinley Park smoke detectors need to be hardwired?
Yes. The code requires dual voltage, 120V with battery back-up, detectors wired in series on every level of the home and in every bedroom, which goes beyond a battery-only smoke alarm.
What kind of battery must a new smoke alarm have in Tinley Park?
Under Public Act 100-0200 as applied by § 155.07(E)(2), any new smoke alarm installed in a single-family or multifamily residence must have a mandatory 10-year sealed battery.
Is a smoke detector required near the furnace in a Tinley Park home?
Yes. A 120V smoke detector must be installed near heating units located in normally unoccupied areas such as attics, crawl spaces, and basements, in addition to the detectors required on each level and in bedrooms.

Sources & Official References

Other rules in Tinley Park

All Tinley Park rules

Compare Tinley Park to another location·View the Illinois fire regulations overview

Get notified when Smoke Detectors in Tinley Park, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Smoke Detectors in Nearby Cities

How other cities in Cook County handle smoke detectors.

Chicago, IL
Some Restrictions
Oak Lawn, IL
Some Restrictions
Oak Park, IL
Some Restrictions
Skokie, IL
Some Restrictions
Schaumburg, IL
Some Restrictions
Evanston, IL
Some Restrictions