Troy, MI Fire Regulations: Smoke Detectors (2026)
Key Facts
- Required locations
- outside sleeping areas, in bedrooms, every story
- Power source
- building wiring with battery backup
- Low-battery signal
- required
- Multiple alarms
- must be interconnected
- Governing chapter
- Chapter 82, not Chapter 93
Summary
Troy's Property Maintenance Code requires smoke alarms outside every sleeping area, in every bedroom and on every story of a dwelling unit, wired to house power with battery backup, and interconnected so one alarm triggers all of them within the unit. The rule sits in Chapter 82, Section 704, not Chapter 93.
704.2 Smoke alarms. Single or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and in dwellings not regulated in Group R occupancies, regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements and cellars but not including crawl spaces and uninhabitable attics. 704.3 Power source. In Group R occupancies and in dwellings not regulated as Group R occupancies, single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms shall emit a signal when the batteries are low.
Full Breakdown
2 of Chapter 82 (Property Maintenance Code) requires single or multiple-station smoke alarms in Groups R-2, R-3, R-4 and in dwellings not otherwise regulated as a Group R occupancy, regardless of occupant load, at three locations: on the ceiling or wall outside each separate sleeping area near bedrooms, in each room used for sleeping, and in each story of the dwelling unit including basements and cellars (crawl spaces and uninhabitable attics excluded). A split-level unit without an intervening door between levels can rely on the upper-level alarm to cover an adjacent lower level less than one full story below.
3 requires alarms in Group R occupancies to draw primary power from building wiring fed by a commercial source, backed up by battery, and to signal when batteries run low, with an exception allowing battery-only alarms in buildings not served by commercial power or during limited alterations that don't expose the structure. 4 requires interconnection where more than one alarm is installed in a unit, so activating one activates all of them, audible in every bedroom over background noise with doors closed, subject to exceptions for buildings not undergoing alteration or construction.
1 ties the whole chapter to the Troy Fire Code (Chapter 93) for fire protection systems generally, but the smoke-alarm text itself is codified in Chapter 82.
Violations & Fines
A dwelling missing a required smoke alarm, running one on the wrong power source, or lacking required interconnection is a Chapter 82 violation, enforced as a municipal civil infraction under Section 106.1 and Chapter 100. The code official may issue a notice or citation under Section 107.1, and each day a violation continues after notice is a separate offense under Section 106.2.
Frequently Asked Questions
Where does Troy require smoke alarms in a dwelling?
Can a Troy dwelling use battery-only smoke alarms?
Do multiple smoke alarms in one unit have to be linked?
Sources & Official References
Other rules in Troy
Compare Troy to another location·View the Michigan fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Smoke Detectors in Nearby Cities
How other cities in Oakland County handle smoke detectors.