Gulfport, MS Hurricane Preparedness: Roof Standards (2026)
Key Facts
- Standard adopted
- ICC 600, 2014 edition
- Governing section
- Code Sec. 3-34(a)
- Enforced by
- Building Official
- Appeal deadline
- 15 days, Sec. 3-36
- General penalty
- Up to $1,000 or 90 days
- Prior edition
- 2008 ed. adopted by Ord. 2818
Summary
Gulfport requires new and altered residential buildings to meet ICC 600, the 2014 Standard for Residential Construction in High Wind Regions, adopted at Code Sec. 3-34 as the city's high-wind construction code. The standard sets prescriptive wind-resistant design and construction details, including roof framing and connections, for homes built in this hurricane-exposed Gulf Coast city, enforced through the building permit process.
That certain document, one (1) copy of which is on file in the office of the Building Official of the City of Gulfport, being marked and designated as the ICC 600 (Standard for Residential Construction in High Wind Regions), 2014 edition, as published by the International Code Council, be and is hereby adopted as the high wind residential construction code of the City of Gulfport, Mississippi, for regulating and governing the design and construction of residential buildings in high-wind regions and to specify prescriptive methods to provide wind-resistant designs and construction details for residential buildings constructed in high-wind regions.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 68).
Full Breakdown
The City of Gulfport adopted the International Code Council's ICC 600, 2014 edition, as its high-wind residential construction code at Code of Ordinances Sec. 3-34(a), governing the design and construction of residential buildings in high-wind regions and specifying prescriptive methods for wind-resistant designs and construction details, which necessarily reach roof framing, sheathing attachment and roof-to-wall connections since those are the assemblies ICC 600 is written to address. The city first adopted the 2008 edition of ICC 600 by Ordinance No. 2818 in 2014 and updated to the current 2014 edition by Ordinance No.
2968 on August 7, 2018, replacing an original 1994 adoption under Ordinance No. 1977. An editor's note to that 1994 ordinance preserves a conflicts rule still in force: where an existing city ordinance conflicts with the hurricane residential construction manual, the most restrictive code, standard or regulation controls. Compliance is checked through the same building permit and plan-review process required for any building permit under Sec. 3-31, which sets a base permit fee of thirty dollars plus a graduated fee schedule tied to the value of the work, with half paid at plan submission and the balance at permit issuance.
The Building Official administers the standard, and appeals from the Building Official's decisions go to the Construction Board of Adjustment and Appeals: a written notice of appeal must be filed within fifteen days, with the board certifying a transcript and the city council hearing the appeal within sixty days of receiving the record, per Sec. 3-36.
Violations & Fines
No penalty is stated inside Sec. 3-34 itself, so a violation of the high-wind construction code falls under the Code's general penalty at Sec. 1-9: a fine of up to one thousand dollars, imprisonment of up to ninety days, or both, with each day a violation continues treated as a separate offense. Non-compliant work can also be denied a certificate of occupancy by the Building Official until brought into compliance.
Frequently Asked Questions
Does Gulfport require homes to be built to a hurricane wind standard?
What happens if the high-wind code conflicts with another Gulfport ordinance?
How do I appeal a Building Official decision under the high-wind code?
Sources & Official References
Other rules in Gulfport
Compare Gulfport to another location·View the Mississippi hurricane preparedness overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.