Key Facts
- Pre-1980 unit limit
- 60 dBA at property line
- Post-1980 unit limit
- 55 dBA at property line
- Patio/window limit (post-1980)
- 50 dBA
- Measurement standard
- ASHRAE Code of Recommended Practices
- Max penalty
- $500 fine / 180 days jail
Summary
Long Beach sets fixed decibel ceilings for air-conditioning and refrigeration equipment measured at the neighboring property line, patio and window, with older units (pre-1980) allowed 5 dBA more than units installed since.
N.Air-conditioning or air refrigerating equipment. Operating or permitting the operation of any air-conditioning or air refrigerating equipment in such a manner as to exceed any of the following sound levels measured as specified in the American Society of Heating, Refrigeration and Air Conditioning Engineers Code of Recommended Practices: Any point on neighboring property line, five feet above grade level, no closer than three feet from any wall - 60 dB(A) Units Before 1-1-80 / 55 dB(A) Units On or After 1-1-80. Center of neighboring patio five feet above grade level, no closer than three feet from any wall - 55/50. Outside the neighboring living area window nearest the equipment location, not more than three feet from the window opening, but at least three feet from any other surface - 55/50. In case of conflict, the interior noise standards as specified in Section 8.80.170 shall nonetheless apply;
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Municipal Code: Supplement 52 Update 1 | City Charter: Supplement 5).
Full Breakdown
200(N) prohibits operating air-conditioning or air-refrigerating equipment above set sound levels, measured per the ASHRAE Code of Recommended Practices, at three locations: on the neighboring property line 5 feet above grade and at least 3 feet from any wall, at the center of a neighboring patio 5 feet above grade, and outside the nearest neighboring living-area window within 3 feet of the opening. Units installed before January 1, 1980 are capped at 60 dBA at the property line, 55 dBA at the patio and 55 dBA at the window; units installed on or after that date are capped 5 dBA lower, 55, 50 and 50 dBA respectively.
170, the interior standard still controls, so an HVAC unit that meets the outdoor table but pushes indoor sound above the Table C interior limits is still a violation. This gives Long Beach residents a specific, checkable installed-date-based standard rather than a generic 'unreasonable noise' test for compressor and condenser units.
Violations & Fines
A homeowner or contractor operating noncompliant HVAC equipment that keeps exceeding these dBA limits after a Noise Control Officer abatement order faces a misdemeanor under § 8.80.380, up to $500 in fines, up to 180 days in jail, or both, with each day of continued violation punishable as a separate offense.
Frequently Asked Questions
How loud can my AC unit be at my neighbor's fence line?
Does the limit change at a patio or window?
Can an AC unit meet the outdoor limit but still violate the code?
What happens if my noisy AC condenser isn't fixed?
Sources & Official References
Other rules in Long Beach
California rules heatmap·Compare Long Beach to another location·View the California noise from specific sources overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
HVAC & Mechanical Noise in Nearby Cities
How other cities in Los Angeles County handle hvac & mechanical noise.